Manuals and User Guides for FE PXR9. We have
1
FE PXR9 manual available for free PDF download: Operation Manual
FE PXR9 Operation Manual (83 pages)
Micro-controller X
Brand:
FE
| Category:
Microcontrollers
| Size: 1.58 MB
Table of Contents
Table of Contents
2
1 Part Names and Functions
6
2 Operations
7
2-1 Parameter List
7
2-2 Basic Operations
12
2-3 Parameter Functions and Method of Settings
14
Manual Mode Setting
15
Standby Setting
16
Local/Remote Operation Setting
17
Ramp-Soak Control
18
Canceling the Alarm Latch
19
Auto-Tuning Function
20
Displaying ON-Delay Alarm or the Remaining Time of Timers
21
Setting Alarm 1, 2 and 3
22
Upper Limit of Alarm 1, 2 and 3
22
Lower Limit of Alarm 1, 2 and 3
22
Key Lock
23
Proportional Band
24
Integral Time
25
Derivative Time
26
Hysteresis Range for ON/OFF Control
27
Cooling-Side Proportional Band Coefficient
28
Cooling-Side Proportional Band Shift (Dead Band/Overlap Band)
29
Output Offset Value
30
Anti-Reset Windup
30
Control Algorithm
31
PV (Measured Value) Stable Range
35
HYS (Hysteresis) Mode at ON/OFF Control
36
Cycle Time of Control Output 1
37
Cycle Time of Control Output 2 (Cooling-Side)
38
Input Signal Code
39
Setting the Measuring Range (Input Range)
40
Selection °C / °F
40
Decimal Point Position
42
PV (Measured Value) Offset
43
SV (Setting Value) Offset
44
Time Constant of Input Filter
45
Alarm Types
46
Selecting Ramp-Soak Patterns
49
Ramp-Soak Status Display
50
1St to 8Th Target SV
50
1St to 8Th Ramp Segment Time
50
1St to 8Th Soak Segment Time
50
Ramp-Soak Modes
50
Specifying Control Action and Output Direction at Input Burn-Out
53
SV (Setting Value) Lower Limiter
54
SV (Setting Value) Upper Limiter
54
The Time of ON-Delay Alarm or Timer Function
55
Displaying Current Detector Input
57
HB (Set Value of Heater Break Alarm)
57
Hysteresis Alarm 1, 2 and 3
59
Options of Alarm 1, 2 and 3
60
Option of Alarm 1, 2 and
60
Upper and Lower Limits for Control Output 1
62
Upper and Lower Limits for Control Output 2
62
Output Limit Types
63
Output Value Display
64
RCJ (Cold Junction Compensation)
65
Adjusting the PV (Measured Value) Display (0%)
66
Adjusting the PV (Measured Value) Display (100%)
66
DI1/2 (Digital Input 1/2) Operation
67
Station No. for Communication
70
Parity for Communication
71
Communication Protocol Setting
72
Re-Transmission Output Type Setting
73
Re-Transmission Base and Span Scale
74
Remote SV Input (0%) Adjustment
75
Remote SV Input (100%) Adjustment
75
Remote SV Input Filter Constant
76
Remote SV Input Value Display
77
Parameter Display Mask
78
3 Troubleshooting
79
Index
81
Advertisement
Advertisement
Related Products
FE PXR4
FE PXR5
FE PXR7
FE PXR3
FE PHW
FE Categories
UPS
Measuring Instruments
Keypad
I/O Systems
Thermostat
More FE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL