Download Print this page

Emerson Powerdrive F300 Reference Manual page 78

Hide thumbs Also See for Powerdrive F300:

Advertisement

Parameter
06.001 Stop Mode
06.003 Supply Loss Mode
06.006 Injection Braking Level
06.007 Injection Braking Time
06.008 Hold Zero Speed
06.009 Catch A Spinning Motor
06.010 Enable Conditions
06.011 Sequencer State Machine Inputs
06.015 Drive Enable
06.016 Date
06.017 Time
06.018 Day Of Week
06.019 Date/Time Selector
06.020 Date Format
06.021 Time Between Filter Changes
06.022 Filter Change Required / Change Done
06.023 Time Before Filter Change Due
06.024 Reset Energy Meter
06.025 Energy Meter: MWh
06.026 Energy Meter: kWh
06.027 Energy Cost Per kWh
06.028 Running Cost
06.029 Hardware Enable
06.030 Run Forward
06.032 Run Reverse
06.033 Forward/Reverse
06.034 Run
06.039 Not Stop
06.040 Enable Sequencer Latching
06.041 Drive Event Flags
06.042 Control Word
06.043 Control Word Enable
06.044 Active Supply
06.045 Cooling Fan control
06.046 Cooling Fan Speed
06.047 Input Phase Loss Detection Mode
06.048 Supply Loss Detection Level
06.051 Hold Supply Loss Active
06.052 Motor Pre‑heat Current Magnitude
06.053 Sleep / Wake Threshold
06.054 Sleep Time
06.055 Wake Time
06.056 Sleep Required
06.057 Sleep Active
06.058 Output Phase Loss Detection Time
06.059 Output Phase Loss Detection Enable
06.060 Standby Mode Enable
06.061 Standby Mode Mask
06.065 Standard Under Voltage Threshold
06.066 Low Under Voltage Threshold
06.067 Low Under Voltage Threshold Select
78
Range
Coast (0), Ramp (1), Ramp dc I (2),
dc I (3), Timed dc I (4)
Disable (0), Ramp Stop (1), Ride Thru (2)
0.0 to 150.0 %
0.0 to 100.0 s
Off (0) or On (1)
Disable (0), Enable (1), Fwd Only (2),
Rev Only (3)
000000000000 to 111111111111
000000 to 111111
Off (0) or On (1)
00-00-00 to 31-12-99
00:00:00 to 23:59:59
Sunday (0), Monday (1), Tuesday (2),
Wednesday (3), Thursday (4), Friday (5),
Saturday (6)
Set (0), Powered (1), Running (2),
Acc Powered (3), Local Keypad (4),
Remote Keypad (5), Slot 1 (6), Slot 2 (7),
Slot 3 (8), Slot 4 (9)
Std (0), US (1)
0 to 30000 Hours
Off (0) or On (1)
0 to 30000 Hours
Off (0) or On (1)
±999.9 MWh
±99.99 kWh
0.0 to 600.0
±32000
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
00 to 11
000000000000000 to 111111111111111
Off (0) or On (1)
Off (0) or On (1)
-10 to 11
0 to 10
Full (0), Ripple Only (1), Disabled (2)
±VM_SUPPLY_LOSS_LEVEL V
Off (0) or On (1)
0 to 100 %
±VM_SPEED_FREQ_REF_UNIPOLAR
0.0 to 250.0 s
0.0 to 250.0 s
Off (0) or On (1)
Off (0) or On (1)
0.5s (0), 1.0s (1), 2.0s (2), 4.0s (3)
Disabled (0), Phases (1), Devices (2)
Off (0) or On (1)
0000000 to 1111111
±VM_STD_UNDER_VOLTS V
±VM_LOW_UNDER_VOLTS V
Off (0) or On (1)
Default
Ramp (1)
RW
Txt
Disable (0)
RW
Txt
100.0 %
RW Num
1.0 s
RW Num
Off (0)
RW
Bit
Disable (0)
RW
Txt
RO
Bin
RO
Bin
On (1)
RW
Bit
RW Date ND NC PT
RW Time ND NC PT
RO
Txt
Local Keypad (4)
RW
Txt
Std (0)
RW
Txt
0 Hours
RW Num
RW
Bit
RO Num ND NC PT PS
Off (0)
RW
Bit
RO Num ND NC PT PS
RO Num ND NC PT PS
0.0
RW Num
RO Num ND NC PT
RO
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
00
RW Bin
000000000000000
RW Bin
Off (0)
RW
Bit
RO
Bit
10
RW Num
RO Num ND NC PT
Full (0)
RW
Txt
200V drive: 205 V
400V drive: 410 V
RW Num
575V drive: 540 V
690V drive: 540 V
Off (0)
RW
Bit
0 %
RW Num
0.0
RW Num
10.0 s
RW Num
10.0 s
RW Num
RO
Bit
RO
Bit
0.5s (0)
RW
Txt
Disabled (0)
RW
Txt
Off (0)
RW
Bit
0000000
RW Bin
200V drive: 175 V
400V drive: 330 V
RW Num
575V drive: 435 V
690V drive: 435 V
200V drive: 175 V
400V drive: 330 V
RW Num
575V drive: 435 V
690V drive: 435 V
Off (0)
RW
Bit
Powerdrive F300 Parameter Reference Guide
Type
US
US
RA
US
US
US
US
ND NC PT
ND NC PT
US
ND NC PT
US
US
US
ND NC
US
ND NC PT
NC
NC
NC
NC
NC
US
NC
NC
US
ND NC PT
US
US
RA
US
NC
US
US
US
US
ND NC PT
ND NC PT
US
US
US
US
RA
US
RA
US
US
Issue: 01.15.00

Advertisement