Emerson Powerdrive F300 Reference Manual page 172

Hide thumbs Also See for Powerdrive F300:

Advertisement

Motor Overload Alarm (10.017) is set if the drive output current is higher than the level that will eventually cause a Motor Too Hot trip and
the Motor Protection Accumulator (04.019) is higher than 75.0%. See Motor Thermal Time Constant 1 (04.015) for more details.
Parameter
10.018 Drive Over-temperature Alarm
Short description
Indicates that the drive over-temperature alarm is active
Mode
Open‑Loop
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Drive Over-temperature Alarm (10.018) is set if Percentage Of Drive Thermal Trip Level (07.036) is greater than 90%.
Parameter
10.019 Drive Warning
Short description
Indicates that one or more of the drive warning alarms are active
Mode
Open‑Loop
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Drive Warning (10.019) is set to one if any of the drive warnings is active, and is defined as:
Drive Warning (10.019) = Braking Resistor Alarm (10.012) OR Motor Overload Alarm (10.017) OR Drive Over-temperature Alarm (10.018)
OR Low Load Detected Alarm (10.062)
Parameter
10.020 Trip 0
Short description
Shows the current or last trip to have occurred
Mode
Open‑Loop
Minimum
0
Default
Type
8 Bit Power Down Save
Display Format
Standard
Coding
RO, TE, ND, NC, PT, BU
Click here to view trips in numerical order.
172
Maximum
1
Units
Update Rate
Background write
Decimal Places
0
Maximum
1
Units
Update Rate
Background write
Decimal Places
0
Maximum
255
Units
Update Rate
Write on trip
Decimal Places
0
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00