Download Print this page

Emerson Powerdrive F300 Reference Manual page 54

Hide thumbs Also See for Powerdrive F300:

Advertisement

maximum current reference vector (I
The drive can have a heavy duty rating intended for applications where high overload current may be required under transient conditions, or it can have
a normal duty rating where a lower level of overload current is required. The duty rating is selected automatically by the drive based on the setting of
Rated Current (05.007). The Maximum Heavy Duty Rating (11.032) and Maximum Rated Current (11.060) are fixed for each drive size and the table
below shows the possible duty ratings that can be selected depending on the levels of these parameters.
Conditions
Maximum Heavy Duty Rating (11.032) = 0.00
Maximum Heavy Duty Rating (11.032) <
Maximum Rated Current (11.060)
Maximum Heavy Duty Rating (11.032) =
Maximum Rated Current (11.060)
The different duty ratings modify the motor protection characteristic (see Motor Thermal Time Constant 1 (04.015)). The different duty ratings can also
change the level of I
as described previously.
MaxRef
In a drive that contains multiple power modules Full Scale Current Kc (11.061) is the full scale current of an individual module multiplied by the number
of modules. Maximum Heavy Duty Rating (11.032) and Maximum Rated Current (11.060) are the value for an individual module multiplied by the
number of modules.
54
) is equal to 1.1 x Maximum Rated Current (11.060) or 0.7 x Kc whichever is lower.
MaxRef
Possible duty ratings
Normal duty operation only
Heavy duty operation if rated current > MAX, otherwise
normal duty operation
Heavy duty operation only
Powerdrive F300 Parameter Reference Guide