Parameter
06.076 Low Voltage Braking IGBT Threshold Select
Short description
Set to 1 enable low voltage IGBT braking
Mode
Open‑Loop
Minimum
0
Default
0
Type
1 Bit Volatile
Display Format
Standard
Coding
RW
See Low Voltage Braking IGBT Threshold (06.075).
Parameter
06.084 Date And Time Offset
Short description
Date And Time Offset
Mode
Open‑Loop
Minimum
-24.00
Default
0.00
Type
16 Bit User Save
Display Format
Standard
Coding
RW
Date And Time Offset (06.084) is an offset, specified in hours, that can be applied to the Time (06.017). If the offset applied causes the time to roll-over
midnight then the Date (06.016) and Day Of Week (06.018) are also modified. The offset is only applied when the clock source is a clock derived from a
keypad or option module, i.e. Date/Time Selector (06.019) > 3. The offset can be used for time zone offsets or daylight saving time etc. It should be noted
that when the date and time is derived from an option module this may be in the form of UTC (Coordinated Universal Time) with an additional offset also
provided by the option module. The data and time is derived by adding the additional offset and the time from the option module and then
adding Date And Time Offset (06.084).
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Maximum
1
Units
Update Rate
4ms read
Decimal Places
0
Maximum
24.00
Units
Hours
Update Rate
Background Read
Decimal Places
2