Parameter
08.018 24V Supply Output Invert
Short description
Set to invert 24V Supply Output
Mode
Open‑Loop
Minimum
0
Default
1
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE
Value
Text
0
Not Invert
1
Invert
See Digital I/O 01 Invert (08.011).
Parameter
08.020 Digital I/O Read Word
Short description
Displays the states for digital I/O 1 to 8
Mode
Open‑Loop
Minimum
0
Default
Type
16 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Digital I/O Read Word (08.020) reflects the state of digital input/output 1 to STO input 1 as given below. Each bit matches the value of the state
parameter for the respective digital input or output.
Digital I/O Read Word (08.020) bit
0
1
2
3
4
5
6
7
8
Parameter
08.021 Digital I/O 01 Source/Destination
Short description
Defines the source or destination parameter for Digital I/O 1
Mode
Open‑Loop
Minimum
0.000
Default
10.002
Type
16 Bit User Save
Display Format
Standard
Coding
RW, DE, PT, BU
The Digital I/O Source/Destination parameters provide the routing for the source and/or destination for the digital I/O.
Parameter
08.022 Digital I/O 02 Source/Destination
Short description
Defines the source or destination parameter for Digital I/O 2
Mode
Open‑Loop
Minimum
0.000
Default
10.033
Type
16 Bit User Save
Display Format
Standard
Coding
RW, DE, PT, BU
See Digital I/O 01 Source/Destination (08.021).
Parameter
08.023 Digital I/O 03 Source/Destination
Short description
Defines the source or destination parameter for Digital I/O 3
Mode
Open‑Loop
Minimum
0.000
Default
6.030
Type
16 Bit User Save
Display Format
Standard
Coding
RW, DE, PT, BU
132
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Digital I/O
Digital I/O 1
Digital I/O 2
Digital I/O 3
Digital Input 4
Digital Input 5
Digital Input 6
Relay
24V Output
STO Input 1
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
1
Background read
0
511
Background write
0
59.999
Drive Reset Read
3
59.999
Drive Reset Read
3
59.999
Drive Reset Read
3
Powerdrive F300 Parameter Reference Guide