Parameter
11.054 Drive Date Code
Short description
Shows the drive date code
Mode
Open‑Loop
Minimum
0
Default
Type
16 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT, BU
Drive Date Code (11.054) is a four-digit number in the form yyww where yy is the year and ww the week number.
Parameter
11.055 Onboard User Program: Clock Task Scheduled Interval
Short description
Displays the interval at which the clock task is scheduled in ms
Mode
Open‑Loop
Minimum
0
Default
Type
32 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Onboard User Program: Clock Task Scheduled Interval (11.055) shows the interval at which the clock task is scheduled to run at in ms.
Parameter
11.056 Option Slot Identifiers
Short description
Defines the order that option slots are used by the drive
Mode
Open‑Loop
Minimum
0
Default
0
Type
8 Bit Volatile
Display Format
Standard
Coding
RW, TE, PT
Value
Text
0
1234
1
1243
2
1324
3
1342
4
1423
5
1432
6
4123
7
3124
8
4132
9
2134
10
3142
11
2143
12
3412
13
4312
14
2413
15
4213
16
2314
17
3214
18
2341
19
2431
20
3241
21
3421
22
4231
23
4321
If Option Slot Identifiers (11.056) is set to its default value of 0 each option module is assigned the same slot number as its physical slot. For example
the module in physical slot 1 appears in slot 1 to all drive and option module software systems (i.e. it uses Menu 15 as its set-up menu and Menu 25 as
its application menu etc.). This arrangement can be changed by selecting a different value for Option Slot Identifiers (11.056). Although
Option Slot Identifiers (11.056) is a volatile parameter its value is saved in non-volatile memory when parameters are saved. If Option Slot Identifiers
(11.056) is changed the drive must be powered down and then powered up again for the change to take effect.
210
Maximum
65535
Units
Update Rate
Background write
Decimal Places
0
Maximum
262140
Units
ms
Update Rate
Background write
Decimal Places
0
Maximum
23
Units
Update Rate
Power-up and drive reset read
Decimal Places
0
Powerdrive F300 Parameter Reference Guide