Parameter
11.091 Additional Identifier Characters 1
Short description
Displays the additional identifier characters
Mode
Open‑Loop
Minimum
-2147483648
Default
Type
32 Bit Volatile
Display Format
String
Coding
RO, ND, NC, PT
See Product Identifier Characters (11.064).
Parameter
11.092 Additional Identifier Characters 2
Short description
Displays the additional identifier characters
Mode
Open‑Loop
Minimum
-2147483648
Default
Type
32 Bit Volatile
Display Format
String
Coding
RO, ND, NC, PT
See Product Identifier Characters (11.064).
Parameter
11.093 Additional Identifier Characters 3
Short description
Displays the additional identifier characters
Mode
Open‑Loop
Minimum
-2147483648
Default
Type
32 Bit Volatile
Display Format
String
Coding
RO, ND, NC, PT
See Product Identifier Characters (11.064).
Parameter
11.095 Number Of Rectifiers Detected
Short description
Number Of Rectifiers Detected
Mode
Open‑Loop
Minimum
0
Default
Type
8 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Indicates how many controlled rectifiers connected to the drive have been detected. See Number Of Rectifiers Expected (11.096).
Parameter
11.096 Number Of Rectifiers Expected
Short description
Number of rectifiers expected on each power stage
Mode
Open‑Loop
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW
Number Of Rectifiers Expected (11.096) defines how many controlled rectifiers are expected on each power module. Within a complete drive with a
diode input stage there are no controlled rectifiers. Within a complete drive with a controlled rectifier input stage there is one controlled rectifier. For a
drive where external rectifiers are used the system can register up to nine controlled rectifiers. If Number Of Rectifiers Expected (11.096) = 0 then the
rectifier monitoring system is disabled and the drive does not check how many controlled rectifiers are present. This is the default setting and should be
used for complete drives with internal rectifiers because the monitoring function is not necessary. If Number Of Rectifiers Expected (11.096) is set to a
non-zero value a check is made to ensure that at least this number of external rectifiers are connected to each power module. If there are less external
rectifiers than defined by Number Of Rectifiers Expected (11.096) then a Configuration is initiated with the sub-trip indicating how many rectifers should
be present. See Trip 0 (10.020).
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Maximum
2147483647
Units
Update Rate
Power-up write
Decimal Places
0
Maximum
2147483647
Units
Update Rate
Power-up write
Decimal Places
0
Maximum
2147483647
Units
Update Rate
Power-up write
Decimal Places
0
Maximum
9
Units
Update Rate
Background Write
Decimal Places
0
Maximum
9
Units
Update Rate
Background Read
Decimal Places
0
217