Download Print this page

Emerson Powerdrive F300 Reference Manual page 44

Hide thumbs Also See for Powerdrive F300:

Advertisement

Deceleration Rate Select Bit 2
(02.037)
0
0
0
0
1
1
1
1
Parameter
02.021 Deceleration Rate 1
Short description
Defines the deceleration rate present in deceleration rate 1
Mode
Open‑Loop
Minimum
−VM_ACCEL_RATE
Default
20.0
Type
32 Bit User Save
Display Format
Standard
Coding
RW, VM
Deceleration Rate 1 (02.021) to Deceleration Rate 8 (02.028) can be selected to define the linear ramp rate. The deceleration rate applies when the
frequency/speed is changing towards zero.
Selecting a ramp rate that has been set to zero in Open-loop mode disables the ramp system so that the Post Ramp Reference (02.001) follows thePre-
ramp Reference (01.003) without any delay for acceleration or deceleration. It should be noted that this also disables the standard ramp d.c. link voltage
controller and the frequency based current limits.
The units of Deceleration Rate 1 (02.021) to Deceleration Rate 8 (02.028) are s / Ramp rate frequency or s / Ramp rate speed. See Ramp Rate Units
(02.039) for the definition of Ramp rate frequency and Ramp rate speed.
Parameter
02.022 Deceleration Rate 2
Short description
Defines the deceleration rate present in deceleration rate 2
Mode
Open‑Loop
Minimum
−VM_ACCEL_RATE
Default
20.0
Type
32 Bit User Save
Display Format
Standard
Coding
RW, VM
See Deceleration Rate 1 (02.021).
Parameter
02.023 Deceleration Rate 3
Short description
Defines the deceleration rate present in deceleration rate 3
Mode
Open‑Loop
Minimum
−VM_ACCEL_RATE
Default
20.0
Type
32 Bit User Save
Display Format
Standard
Coding
RW, VM
See Deceleration Rate 1 (02.021).
Parameter
02.024 Deceleration Rate 4
Short description
Defines the deceleration rate present in deceleration rate 4
Mode
Open‑Loop
Minimum
−VM_ACCEL_RATE
Default
20.0
Type
32 Bit User Save
Display Format
Standard
Coding
RW, VM
See Deceleration Rate 1 (02.021).
44
Deceleration Rate Select Bit 1
(02.036)
0
0
1
1
0
0
1
1
Deceleration Rate Select Bit 0
(02.035)
0
1
0
1
0
1
0
1
Maximum
VM_ACCEL_RATE
Units
s
Update Rate
4ms read
Decimal Places
1
Maximum
VM_ACCEL_RATE
Units
s
Update Rate
4ms read
Decimal Places
1
Maximum
VM_ACCEL_RATE
Units
s
Update Rate
4ms read
Decimal Places
1
Maximum
VM_ACCEL_RATE
Units
s
Update Rate
4ms read
Decimal Places
1
Deceleration rate
selected
Deceleration Rate 1
(02.021)
Deceleration Rate 2
(02.022)
Deceleration Rate 3
(02.023)
Deceleration Rate 4
(02.024)
Deceleration Rate 5
(02.025)
Deceleration Rate 6
(02.026)
Deceleration Rate 7
(02.027)
Deceleration Rate 8
(02.028)
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00

Advertisement

loading