Emerson Powerdrive F300 Reference Manual page 318

Hide thumbs Also See for Powerdrive F300:

Advertisement

Trip
Power Data
Value
220
Short description
This trip can be generated either from the drive control system or from the power system.
This trip is produced if there is an error in the configuration data stored in the power system. If the source of the trip is the control system then the trip related to the
table that is uploaded from the power system at power-up.
Source
xx
Control
00
system
Control
00
system
Control
00
system
Control
00
system
Control
00
system
Control
00
system
Power system 01
Power system 01
Power system 01
Recommended actions:
Hardware fault - contact the supplier of the drive.
Trip
Power Down Save
Value
37
Short description
This trip indicates that an error has been detected in the power down save parameters stored in non-volatile memory.
Recommended actions:
Perform a 1001 save in Pr mm.000 to ensure that the trip doesn't occur the next time the drive is powered up.
Trip
PSU
Value
5
Short description
This trip indicates that one or more internal power supply rails are outside limits or overloaded.
Source
xx
Control
00
system
Power module
Power system
number
*For a parallel power-module system the rectifier number will be zero as it is not possible to determine which rectifier has detected the fault.
Recommended actions:
318
y
zz
0
02: There is no data table to be uploaded to the control board.
03: The power system data table is bigger than the space available in the
0
control pod to store it.
0
04: The size of the table given in the table is incorrect
0
05: Table CRC error.
06: The version number of the generator software that produced the table is
0
too low, i.e. a table from a newer generator is required that includes features
that have been added to the table that may not be present.
07: The power board data table does not
0
match the power board hardware identifier.
00: The power data table used internally by the power module has an error.
0
(For a multi-power module drive this indicates any error with the code tables
in the power system.)
01: The power data table that should be uploaded to the control system on
0
power up has an error.
02: The power data table used internally by the power module does not
0
match the hardware identification of the power module.
Y
zz
0
00: Internal power supply overload.
Rectifier
00: Rectifier internal power supply overload.
number*
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00