Parameter mm.000
Parameter mm.000 (mm.000) is one parameter that can be accessed from every drive menu so that the user can initiate various actions by setting a
value in this parameter and then performing a drive reset. If the action is completed successfully parameter mm.000 is cleared when the action is
complete. If the action is not started because the value does not correspond to an action, or because the action is not allowed (i.e. an attempt is made
to load defaults and the drive is enabled), parameter mm.000 is not cleared. If the action is started and then fails a trip is produced and parameter
mm.000 is not cleared.
There could be some conflict between the actions of Parameter mm.000 (mm.000) and Parameter Cloning (11.042) when the drive is reset. If
Parameter Cloning (11.042) has a value of 1 or 2 and a valid action is required from the value of parameter mm.000 then only the action required by
parameter mm.000 is performed, but on successful completion of the action both parameters are cleared. If Parameter Cloning (11.042) has any other
value it is not affected.
The table below shows the possible actions that can be initiated with Parameter mm.000 (mm.000).