Download Print this page

Emerson Powerdrive F300 Reference Manual page 325

Hide thumbs Also See for Powerdrive F300:

Advertisement

Sub-trip
Reason
1
The module category cannot be identified
All the required customisable menu table information has not been supplied or the tables supplied
2
are corrupt
3
There is insufficient memory available to allocate the comms buffers for this module.
4
The module has not indicated that it is running correctly during drive power-up
The module has been removed after power-up or it has ceased to indicate to the drive processor
5
that it is still active.
The module has not indicated that it has stopped accessing drive parameters during a drive mode
6
change
7
The module has failed to acknowledge that a request has been made to reset the drive processor.
8
The drive failed to read correctly the menu table from the module during drive power-up.
9
The drive failed to upload menu tables from the module and timed-out (5s).
10
Menu table CRC invalid.
Recommended actions:
Ensure the option module is installed correctly.
Replace the option module.
Replace the drive.
Trip
Slot2 Not Fitted
Value
208
Short description
Each option module fitted in the drive is identified at power-up and the option fitted is stored by the drive in its non-volatile memory. If an option module was fitted in
slot 2 at power-down, but that option module has subsequently been removed before power up then this trip is produced. The sub-trip number gives the
identification code of the option module that has been removed. The priority order for the option module not fitted trips is Slot1 Not Fitted highest, then
Slot2 Not Fitted, then Slot3 Not Fitted then Slot4 Not Fitted. Drive user parameters must be saved to prevent this trip on the next power-up.
Recommended actions:
Ensure the option module is installed correctly.
Re-install the option module.
To confirm that the removed option module is no longer required perform a save function in Pr mm.000.
Trip
Slot2 Watchdog
Value
206
Short description
This trip indicates that the option module in option slot 2 has started the option watchdog function and then failed to service this watchdog correctly.
Recommended actions:
Replace the option module.
Trip
Slot3 Different
Value
214
Short description
If the option module fitted in option slot 3 is different to the option module present at the last power-down then this trip is produced. The sub-trip number gives the
identification code of the module that was originally fitted. The priority order for the option module different trips is Slot1 Different highest, then Slot2 Different, then
Slot3 Different then Slot4 Different. Drive user parameters must be saved to prevent this trip on the next power-up if the module has changed. If the menus have
been changed, but not the module, the trip will not occur on the next power-up. The sub-trip number gives the following indications of the reason for the trip.
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
325

Advertisement

loading