Parameter
08.063 24V Supply Input Destination
Short description
Defines the destination parameter for the 24V input
Mode
Open‑Loop
Minimum
0.000
Default
0.000
Type
16 Bit User Save
Display Format
Standard
Coding
RW, DE, PT, BU
See Digital I/O 01 Source/Destination (08.021).
Parameter
08.065 Relay 2 Source
Short description
Defines the source parameter for the relay 2 output
Mode
Open‑Loop
Minimum
0.000
Default
0.000
Type
16 Bit User Save
Display Format
Standard
Coding
RW, PT, BU
See Digital I/O 01 Source/Destination (08.021).
Parameter
08.071 Digital I/O Output Enable Register 1
Short description
Displays the binary form of the DI/O output enable register
Mode
Open‑Loop
0
Minimum
(Display: 0000000000000000)
0
Default
(Display: 0000000000000000)
Type
16 Bit User Save
Display Format
Binary
Coding
RW, PT, BU
The bits in the Digital I/O Output Enable Register 1 (08.071), Digital I/O Input Register 1 (08.072) and Digital I/O Output Register 1 (08.073) each
correspond with one digital I/O as shown below. The update rate of the individual bits in these registers differs depending upon the I/O.
DI/O Bit Function
1
0
Digital Input/Output
2
1
Digital Input/Output
3
2
Digital Input/Output
4
3
Digital Input
5
4
Digital Input
6
5
Digital Input
7
6
Relay Output
8
7
24V Supply Output
9
8
Safe Torque Off 1
10
9
Safe Torque Off 2
11
10 Keypad Run Button
12
11 Keypad Auxiliary Button
13
12 24V Supply Input
14
13 Keypad Stop Button
15
14 Relay 2 Output
16
15 Drive Reset Button
The Digital I/O Input Register 1 (08.072) is always active and shows the value in the Digital I/O State parameter for all digital I/O configured as inputs.
Bits in the Digital I/O Output Register 1 (08.073) can be used to control the digital I/O directly. The bits control the output directly and are not modified by
the corresponding Digital I/O Invert/Toggle function. The bits in the Digital I/O Output Register 1 (08.073) only control the corresponding digital output if
all the conditions below are met:
1. The corresponding bit in the Digital I/O Output Enable Register 1 (08.071) must be set to 1.
2. The digital I/O must be an output, or it must be an input/output and the corresponding Digital I/O Output Select parameter must be one.
3. The corresponding Digital I/O Source/Destination parameter is not as valid source (e.g. 0.000) and the drive has been powered-up or reset
since it was first selected.
If the above conditions are not met, the digital output is controlled by the normal logic.
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Bit update rate
Input Register
Output Register
2ms
250μs
2ms
250μs
2ms
2ms
250μs
Not applicable
250μs
Not applicable
2ms
Not applicable
Bit always 0
2ms
Bit always 0
2ms
2ms
Not applicable
2ms
Not applicable
Background
Not applicable
Background
Not applicable
2ms
Not applicable
Background
Not applicable
Bit always 0
2ms
Background
Not applicable
59.999
Drive Reset Read
3
59.999
Drive Reset Read
3
65535
(Display: 1111111111111111)
Background read
0
Output Enable Register
Background
Background
Background
Not applicable
Not applicable
Not applicable
Background
Background
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Background
Not applicable
137