Download Print this page

Emerson Powerdrive F300 Reference Manual page 243

Hide thumbs Also See for Powerdrive F300:

Advertisement

Parameter
14.053 PID2 Reference Scaling
Short description
Defines the scaling factor for the reference for PID2
Mode
Open‑Loop
Minimum
0.000
Default
1.000
Type
16 Bit User Save
Display Format
Standard
Coding
RW
See PID1 Reference Scaling (14.023).
Parameter
14.054 PID2 Feedback Scaling
Short description
Defines the scaling factor of the feedback for PID2
Mode
Open‑Loop
Minimum
0.000
Default
1.000
Type
16 Bit User Save
Display Format
Standard
Coding
RW
See PID1 Feedback Scaling (14.024).
Parameter
14.055 PID2 Digital Reference
Short description
Defines the value of the digital reference for PID2
Mode
Open‑Loop
Minimum
-100.00
Default
0.00
Type
16 Bit User Save
Display Format
Standard
Coding
RW
See PID1 Digital Reference (14.025).
Parameter
14.056 PID2 Digital Feedback
Short description
Defines the value of the digital feedback for PID2
Mode
Open‑Loop
Minimum
-100.00
Default
0.00
Type
16 Bit User Save
Display Format
Standard
Coding
RW
See PID1 Digital Feedback (14.026).
Parameter
14.057 PID2 Enable Source 2
Short description
Defines the input source for enabling PID2
Mode
Open‑Loop
Minimum
0.000
Default
0.000
Type
16 Bit User Save
Display Format
Standard
Coding
RW, PT, BU
See PID1 Enable Source 2 (14.027).
Parameter
14.058 PID1 Feedback Output Scaling
Short description
Defines the scaling factor of the output feedback for PID1
Mode
Open‑Loop
Minimum
0.000
Default
1.000
Type
16 Bit User Save
Display Format
Standard
Coding
RW
PID1 alternative feedback and error selection
The description given in PID1 Output (14.001) assumed that PID1 Mode Selector (14.059) = 0 so that PID controller 1 uses its own feedback (FBK1).
It is possible to select alternative configurations that allow various combinations of feedback or error from either PID controller to be used as shown
below.
Powerdrive F300 Parameter Reference Guide
Issue: 01.15.00
Maximum
4.000
Units
Update Rate
4ms read
Decimal Places
3
Maximum
4.000
Units
Update Rate
4ms read
Decimal Places
3
Maximum
100.00
Units
%
Update Rate
4ms read
Decimal Places
2
Maximum
100.00
Units
%
Update Rate
4ms read
Decimal Places
2
Maximum
59.999
Units
Update Rate
Drive reset read
Decimal Places
3
Maximum
4.000
Units
Update Rate
4ms read
Decimal Places
3
243

Advertisement

loading