Tolerance; Regulation; Input Voltage Characteristics - Kontron CP6003-SA User Manual

6u compactpci processor board based on the 2nd generation intel core i7/i5 processor with the intel qm67 express chipset
Table of Contents

Advertisement

CP6003-SA
5.1.3.3

Tolerance

The tolerance of the voltage lines is described in the CompactPCI specification (PICMG 2.0
R3.0). The recommended measurement point for the voltage is the CompactPCI connector on
the CPU board.
The following table provides information regarding the required characteristics for each board
input voltage.
Table 5-3:

Input Voltage Characteristics

VOLTAGE
NOMINAL VALUE
5 V
3.3 V
+12 V
-12 V
VI/O (PCI) voltage
+3.3 VDC or +5 VDC
GND
The output voltage overshoot generated during the application (load changes) or during the
removal of the input voltage must be less than 5% of the nominal value. No voltage of reverse
polarity may be present on any output during turn-on or turn-off.
5.1.3.4

Regulation

The power supply shall be unconditionally stable under line, load, unload and transient load
conditions including capacitive loads. The operation of the power supply must be consistent
even without the minimum load on all output lines.
Warning!
All of the input voltages must be functionally coupled to each other so that if
one input voltage fails, all other input voltages must be regulated proportion-
ately to the failed voltage. For example, if the +5V begins to decrease, all other
input voltages must decrease accordingly. This is required in order to preclude
cross currents within the CP6003-SA.
Failure to comply with above may result in damage to the board or improper
system operation.
Note ...
If the main power input is switched off, the supply voltages will not go to 0V
instantly. It will take a couple of seconds until the capacitors are discharged. If
the voltage rises again before it has gone below a certain level, the circuits
may enter a latch-up state where even a hard RESET will not help any more.
The system must be switched off for at least 3 seconds before it may be
switched on again. If problems still occur, turn off the main power for 30 sec-
onds before turning it on again.
ID 1044-9757, Rev. 2.0
TOLERANCE
+5.0 VDC
+5%/-3%
+3.3 VDC
+5%/-3%
+12 VDC
+5%/-5%
-12 VDC
+5%/-5%
+5%/-3%
Ground, not directly connected to potential earth (PE)
Power Considerations
MAX. RIPPLE (p-p)
50 mV
50 mV
240 mV
240 mV
50 mV
REMARKS
Main voltage
Required
Not required
Page 5 - 5