IAI SP-20000M-CXP2 User Manual page 67

20 mp cmos digital progressive scan monochrome and color camera spark series
Hide thumbs Also See for SP-20000M-CXP2:
Table of Contents

Advertisement

SP-20000M-CXP2 / SP-20000C-CXP2
Acquisition Start
Set "Index 0"
Trigger In
Input
Execute Index Table
[Sequence ROI Frame Count]
Decrement value : -1
[Sequence
ROI
Frame Count]
Decrement
value
= 0
Next Index
= Off
[Sequence Repetition]
Decrement value: -1
[Sequence
Repetition]
Decrement
value
= 0
Acquisition Stop
Fig.36
Flow chart of Trigger Sequence
No Input
>≠ 0
If Next Index does
"Off"
not
have
setting, the current
index
table
is
repeated.
≠ Off
Set the index number of
the next index
>≠ 0
- 65 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-20000c-cxp2

Table of Contents