7.5.3

GPIO TTL output timing if Trigger Overlap is OFF

Frame Start -Trigger Mode ="On"
Exposure Mode ="Timed"
Trigger Overlap =OFF
Frame Start
Trigger
Frame
Trigger Wait
Frame Active
Exposure
Active
FVAL Active
Fig. 28
Table - 45 GPIO Out timing (Reference) (Trigger Overlap= OFF)
Description
(a)
Frame Start Trigger
to Frame Trigger Wait Falling Edge
(b)
Exposure Active Falling Edge
to FVAL Rising Edge
(c)
Frame Active Falling Edge
to Frame Trigger Wait Rising Edge
(d)
Exposure Active
(e)
FVAL Active
(f)
Frame Active
(h)
FVAL Falling Edge
to Frame Active Falling Edge
(i)
Frame Trigger wait Falling Edge
to Frame Active Rising Edge
(j)
Frame Active Rising Edge
to Exposure Active Rising Edge
(k)
Frame Start Trigger
to Exposure Active Rising Edge
-
Exposure Active Start Edge :
Internal / TTL Out Phase
-
Exposure Active End Edge:
Internal / TTL Out Phase
Note: The figure in ( ) is the comparison between the exposure time inside camea and Exposure Active
SP-20000M-CXP2 / SP-20000C-CXP-2
(a)
(k)
(i)
(f)
(j)
(d)
(b)
GPIO TTL OUT timing
Tap Geometry:Geometry_1X_1Y
Link Configuration Setting
CXP6_X2
860 ns
304.97 us
(305.22 us)
990 ns
8.61 us
(10.03 us)
30.74 ms
(Intenal:
30.77 ms)
31.08 ms
1.02 us
1.28 us
0.00 us
2.13 us ~
2.16 us
(450 ns~
480 ns)
1.67 us
260 ns
(c)
(h)
(e)
CXP6_X1
CXP3_X1
CXP3_X2
860 ns
1.06 us
304.97 us
610.19 us
(305.22 us)
(610.24 us)
990 ns
1.83 us
8.61 us
8.68 us
(10.03 us)
(10.05 us)
61.53 ms
123.07 ms
(Internal:
( Internal:
61.54 ms )
123.07 ms)
61.85 ms
123.69 ms
1.02 us
0.80 us
1.28 us
1.27 us
0.00 us
0.00 us
2.129 us~
2.312 us~
2.156 us
2.360 us
(450 ns~
(704.00 ns~
480 ns)
754.00 ns)
1.67 us
1.61 us
260 ns
230 ns
- 50 -
Note
If Frame Start Trigger is input from TTL IN
1
(
) is the phase relation between the
exposure time and FVAL inside camera
If Exposure Time = 10.
( ) is the exposure time inside camera
If Binning off and Height=3840
(Varies by the vertical ROI)
If Exposure Mode = Timed
This may vary by binning setting and ROI
setting. The phase of Frame Active End
Edge may vary by 1us against FVAL Active
End.
Exposure Active at TTL I/F output
( ) is the exposure phase relation inside
camera
If the polarity is Active High
If the polarity is Active High