7.6.4

Minimum trigger interval calculation formula (Trigger Overlap = Readout)

Table – 49 Minimum trigger interval calculation formula (Trigger Overlap = Readout)
Camera Settings
Link
Tap
Configuration
Geometry
CXP6_X2
1X – 1Y
CXP6_X1
1X – 1Y
CXP3_X2
CXP3_X1
1X 1Y
Note: For [Trigger Overlap]=Readout setting, if the trigger interval is set longer than the interval desctibed in this table or the
same as the trigger width, the exposure operation might not work properly and as a result, the normal image might not be
output.
SP-20000M-CXP2 / SP-20000C-CXP2
Conditions:
PWC Trigger / Trigger Overlap = Readout
Binning
Vertical
[Unit:us]
1 (Off)
If ROUNDDOWN(((([Height]+1) x 320.5) + 12205 ) ÷ 40MHz x 10^6) +10 - 260
≧ [Trigger Pulse Width]
Result= ROUNDDOWN(((([Height]+1) x 320.5) + 12205 ) ÷ 40MHz x 10^6) +
[Trigger Pulse Width:10us~] )
If ROUNDDOWN(((([Height]+1) x 320.5) + 12205 ) ÷ 40MHz x 10^6) +10 - 260
< [Trigger Pulse Width]
Result=260us+[Trigger Pulse Width]
2 (On)
If ROUNDDOWN(((([Height]+1) x 641) + 12205 ) ÷ 40MHz x 10^6) +10 - 260
≧ [Trigger Pulse Width]
Result= ROUNDDOWN((((([Height]+1) x 641) + 12205 ) ÷ 40MHz x 10^6) +
[Trigger Pulse Width:10us~] )
If ROUNDDOWN(((([Height]+1) x 641) + 12205 ) ÷ 40MHz x 10^6) +10 - 260
< [Trigger Pulse Width]
Result= 260us+[Trigger Pulse Width]
1 (Off)
If ROUNDDOWN(((([Height]+1) x 641) + 12205 ) ÷ 40MHz x 10^6) +10 - 260
≧ [Trigger Pulse Width]
Result= ROUNDDOWN((((([Height]+1) x 641) + 12205 ) ÷ 40MHz x 10^6) +
[Trigger Pulse Width:10us~])
If ROUNDDOWN(((([Height]+1) x 641) + 12205 ) ÷ 40MHz x 10^6) +10 - 260
< [Trigger Pulse Width]
Result=260us+[Trigger Pulse Width]
2 (On)
If ROUNDDOWN(((([Height]+1) x 1282) + 12205 ) ÷ 40MHz x 10^6) +10 - 260
≧ [Trigger Pulse Width]
Result=ROUNDDOWN((((([Height]+1) x 320.5) + 12205 ) ÷ 40MHz x 10^6) +
[Trigger Pulse Width:10us~])
If ROUNDDOWN(((([Height]+1) x 1282) + 12205 ) ÷ 40MHz x 10^6)+10 - 260
< [Trigger Pulse Width]
Result=260us+[Trigger Pulse Width]
1 (Off)
If ROUNDDOWN(((([Height]+1) x 641) + 12205 ) ÷ 20MHz x 10^6) +10 - 520
≧ [Trigger Pulse Width]
Result= ROUNDDOWN((((([Height]+1) x 641) + 12205 ) ÷ 20MHz x 10^6) +
[Trigger Pulse Width:10us~])
If ROUNDDOWN(((([Height]+1) x 641) + 12205 ) ÷ 20MHz x 10^6) +10 - 520
< [Trigger Pulse Width]
Result= 520us+[Trigger Pulse Width]
2 (On)
If ROUNDDOWN(((([Height]+1) x 1282) + 12205 ) ÷ 20MHz x 10^6) +10 - 520
≧ [Trigger Pulse Width]
Result=ROUNDDOWN((((([Height]+1) x 1282) + 12205 ) ÷ 20MHz x 10^6) +
[Trigger Pulse Width:10us~])
If ROUNDDOWN(((([Height]+1) x 1282) + 12205 ) ÷ 20MHz x 10^6) +10 - 520
< [Trigger Pulse Width]
Result=520us+[Trigger Pulse Width]
- 56 -