IAI SP-20000M-CXP2 User Manual page 43

20 mp cmos digital progressive scan monochrome and color camera spark series
Hide thumbs Also See for SP-20000M-CXP2:
Table of Contents

Advertisement

Table – 31 Modes where the exposure control becomes 1L if overlap occurs
JAI Custom Naming
Continuous Trigger
EPS Trigger / LVAL SYNC Reset
HDR
Table – 32
Formula of the exposure time maximum value at the continuous trigger
Camera Settings
Link
Sensor
Configuration
Clock
CXP6_X2
40MHz
CXP6_X1
40MHz
or
CXP3_X2
CXP3_X1
20MHz
Note: [Acquisiiton Frame Rate Raw] is the frame interval [Unit: us].
As an example, the following is for the continuous trigger operation.
Exposure Timing
Internal FVAL
Exposure Active
SP-20000M-CXP2 / SP-20000C-CXP-2
Trigger Mode
Off
On
Off / On
At the continuous trigger operation,
[Exposure Time Max] setting formula
Binning
Vertical
[Unit:us]
1 (Off)
= [Acquisition Frame Rate Raw ] - 250
2 (On)
= [Acquisition Frame Rate Raw ] - 250
1 (Off)
= [Acquisition Frame Rate Raw ] - 250
2 (On)
= [Acquisition Frame Rate Raw ] - 250
1 (Off)
= [Acquisition Frame Rate Raw ] - 500
2 (On)
= [Acquisition Frame Rate Raw ] - 500
Exposure
Time
Fig. 23
Behavior in the continuous trigger operation
Trigger Overlap
(don't care)
Readout
Readout, if the trigger mode
is ON.
If Exposure start and Trigger readout
are overlapped, the exposure start
position is 1Line unit step.。
Frame Rate Time
Acquisition Frame Rate
- 41 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-20000c-cxp2

Table of Contents