5.3.3
Line Mode
Indicates the status of the item selected in Line Selector. (INPUT or OUTPUT)
Table – 6
Associated GenICam register information
GenICam Name
Line Selector
Line Mode
Line Inverter
Line Status
Line Source
Line Format
5.3.4
Line Inverter
Inverts the signal polarity for the item selected in Line Selector. False=Positive, True=Negative)
5.3.5
Line Status
Indicates the status of the selected signal (input or output) (True=High, False=Low)
5.3.6
Line Format
Indicates the interface category of input and output for the selected signal.
Category: No connect, TTL, LVDS and OPTO coupled
SP-20000M-CXP2 / SP-20000C-CXP-2
Access
Line1,2,4,5,7~11
R/W
NAND 0 In1 to 2
NAND 1 In1 to 2
Output
RO
Input
False
R/W
True
False
RO
True
Low
High
Acquisition Trigger Wait
Acquisition Active
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
R/W
PG0 to 3
User out0 to 3
TTL In1
Opt In
CXP In (Trigger Packet)
Nand0 to 1
TTL In2
LVDS In1
TTL
LVDS
RO
Opto
CXP
Values
- 15 -
Category
Digital I/O Control
Digital I/O Control
Digital I/O Control
Digital I/O Control
Digital I/O Control
Digital I/O Control