Trigger Operation; Trigger Selector; Trigger Mode - IAI SP-20000M-CXP2 User Manual

20 mp cmos digital progressive scan monochrome and color camera spark series
Hide thumbs Also See for SP-20000M-CXP2:
Table of Contents

Advertisement

Table – 33
Associated GenICam register information
GenICam Name
Exposure Auto
Exposure Auto Max
Exposure Auto Min
7.3.

Trigger operation

Trigger Source can be selected in Trigger Selector.
In the SP-20000-CXP2, the trigger source can be selected from Frame Start, Acquisition Start
and Acquisition End.
Table - 34
Trigger operation settings
Camera Settings
Trigger
Selector
Trigger
Exposure
Mode
Mode
Frame
Off
Off
Start
Off
Timed
On
Timed
On
Timed
On
Trigger
Width
7.3.1

Trigger Selector

Selects the trigger operation. In the SP-20000-CXP2, the following trigger operation can be
selected as the trigger.
Table – 35
Trigger Selector Item
Frame Start
Acquisition Start
Acqusition End
7.3.2

Trigger Mode

Select either free-running operation or external trigger operation.
OFF: Free-running operation
ON: External trigger operation
SP-20000M-CXP2 / SP-20000C-CXP-2
Access
R/W
R/W
R/W
JAI Custom
Trigger Mode
Trigger
Name
Option
Off
Continuous Trigger
Off
Continuous Trigger
Off
EPS Trigger
PIV
PIV Trigger
Off
PWC Trigger
Trigger selector
Description
Frame Start Trigger operation
Acqusition Start Trigger operation
Acqusition End Trigger operation
Values
Off
Continuous
Once
100 to 8000000
100 to 8000000
Description
Self running operation with the maximum
exposure time per the frame rate
Self running operation with a user-set
exposure time.
Externally triggerred operation with a
user-set exposure time
Externally triggerred operation for PIV
Externally triggerred operation with a
pulse width exposure time
- 43 -
Category
Acquisition Control
JAI-Custom
JAI-Custom