For trigger operation, Exposure Mode must be set to something other than OFF and Trigger Mode of
Frame Start must be ON.
If Exposure Mode is set at Timed, the exposure operation can be selected as follows by setting Trigger
Option
Table – 27
Trigger option
Trigger Option setting
OFF
PIV
The effect of the combination of Exposure Mode, Trigger Option and Trigger Mode is as follows.
Table – 28
The combination of Exposure Mode, Trigger Option and Trigger Mode
Exposure Mode
OFF
Timed
Trigger Width
Table – 29
Associated GenICam register information
GenICam Name
Exposure Mode
Trigger Mode
Trigger Option
SP-20000M-CXP2 / SP-20000C-CXP-2
Exposure operation
Timed (EPS) mode
PIV (Particle Image Velocimetry) mode
Trigger Option
invalidity
OFF
PIV
invalidity
Access
Values
Off
R/W
Timed
TriggerWidth
Off
R/W
On
Off
R/W
PIV
Trigger Mode
(Frame Start)
Self-running operaion
Invalidity
Expsoure control by Exposure Time
is not possible
Self-running operaion
OFF
Expsoure control by Exposure Time
is not possible
Timed (EPS) Operation
ON
Exposure can be controlled by
Exposure Time
PIV Operation
Forced to ON
Exposure can be controlled by
Exposure Time
Exposure is controlled by the pulse
Forced to ON
width of the external trigger