7.5.2
If Overlap setting is Readout
Frame Start Trigger
Frame Trigger Wait
Frame Active
CMOS Exposure
Exposure Active
FVAL
Note: If the trigger overlap is Readout mode, Frame Trigger Wait is active on FVAL period of the
previous trigger. In this period, the next trigger can be accepted. After receiving this
trigger pulse, Frame Trigger Wait becomes inactive.
Tabe – 43 Timing values
Camera Settings
Tap
Vertical
Geometry
Binning
t1
1X – 1Y
t2
1X - 1Y
(Off)
t3
1X -1Y
(On)
SP-20000M-CXP2 / SP-20000C-CXP-2
t2
Read out by previous trigger
Note
Fig. 27
Overlap Readout
Link Configuration
Exposure
Active Signal
source
—
TTL Out
—
Inside
Camera
TTL Out
1
Inside
Camera
TTL Out
2
Inside
Camera
t1
Exposure Period
CXP6_X2
2L(min)
1.680 us
~
1.680 us + 1 Line
460 ns
~
460 ns + 1 Line
305.240 us
307.990 us
305.240 us
307.990 us
- 48 -
t3
CXP6_X1
CXP3_X2
2L(min)
1.680 us
~
1.680 us + 1 Line
2.330 us + 1 Line
460 ns
~
460 ns + 1 Line
710 ns + 1 Line
305.240 us
307.990 us
305.240 us
307.990 us
CXP3_X1
2L(min)
2.330 us
~
710 ns
~
610.170 us
610.400 us
610.170 us
610.400 us