7.3.3

TriggerSource

Select the trigger source to be used for trigger operation from the following table.
Table – 36
Trigger Source
Trigger Source Item
Low
High
Soft Trigger
PulseGenerator0 Out
PulseGenerator1 Out
PulseGenerator2 Out
PulseGenerator3 Out
Line 7 – CXP IN
Line 4 - TTL 1 In
Line -5 – OPTO IN 1
Nand 0 Out
Nand1 Out
User Output 0
User Output 1
User Output 2
User Output 3
Line 10 TTL IN 2
Line 11 LVDS IN
Note:
In the SP-20000-CXP2, GPIO port is located on the AUX interface (Hirose 10P). In this GPIO. Line 10 and Line 11
are available.
7.3.4

TriggerActivation

This command can select how to activate the trigger.
Rising edge:
Falling edge:
Level High:
Level Low:
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
Table - 37
Camera Settings
Trigger
Selector
Trigger
Mode
Frame
On
Start
On
On
SP-20000M-CXP2 / SP-20000C-CXP-2
Description
Connect LOW level signal to the selected trigger operation
Default setting
Connect HIGH level signal to the selected trigger operation
Connect Soft Trigger signal to the selected trigger operation
Trigger can be input manually by the execution of the software trigger
Trigger software is available on each trigger source.
Connect Pulse generator 0 signal to the selected trigger operation
Connect Pulse generator 1 signal to the selected trigger operation
Connect Pulse generator 2 signal to the selected trigger operation
Connect Pulse generator 3 signal to the selected trigger operation
Connect the trigger up-linked from the frame grabber board to the selected trigger
operation
Connect TTL 1 IN signal to the selected trigger operation
Connect OPTO IN 1 signal to the selected trigger operation
Connect NAND 0 OUT signal to the selected trigger operation
Connect NAND 1 OUT signal to the selected trigger operation
Connect User Output 0 signal to the selected trigger operation.
0 or 1 status can be sent by User 0 command from PC(Host side).
Connect User Output 1 signal to the selected trigger operation.
0 or 1 status can be sent by User 0 command from PC(Host side).
Connect User Output 2 signal to the selected trigger operation.
0 or 1 status can be sent by User 0 command from PC(Host side).
Connect User Output 3 signal to the selected trigger operation.
0 or 1 status can be sent by User 0 command from PC(Host side).
Connect TTL 2 IN signal to Line 10
Connect LVDS 1 IN signal to Line 11
At the rising edge of the pulse, the trigger is activated.
At the falling edge of the pulse, the trigger is activated.
During the high level of trigger, the accumulation is activated
During the low level of trigger, the accumulation is activated
Trigger Activation
Trigger
Option
Exposure
Mode
Timed
Off
Timed
PIV
Trigger
Off
Width
JAI Custom
Trigger Activation Setting
Trigger Mode
Rising
Name
Edge
EPS Trigger
PIV Trigger
PWC Trigger
×
- 44 -
Falling
Level
Level
Edge
High
Low
×
×
×
×
×