6.3.2

Vertical timing

In Continuous Trigger operation, the output timing relation is as follows.
The SP-20000M-CXP2 supports H-Binning and V-Binning functions, but the frame rate is not
increased.
Internal FVAL
Internal FVAL
Internal LVAL
Internal LVAL
Internal DVAL
Internal DVAL
Internal DATA
Internal DATA
Exposure Active
Exposure Active
Exposure time (Min)
Table – 16 Vertical format in Continuous Trigger (1/2)
Camera Settings
CXP6
1X_1Y
30.0
_X2
CXP6
_X1
or
1X_1Y
15.0
CXP3
_X2
CXP3
1X_1Y
7.5
_X1
SP-20000M-CXP2 / SP-20000C-CXP-2
FVAL Active (A)
(C) V-Offset
(C) V-Offset
DVAL Active (A)
(F) Exposure End to FVAL Active Start
(F) Exposure End to FVAL Active Start
(D)
(D)
Exposure time (Min)
Fig. 17
Vertical timing relation
ROI
5120
0
3840
0
5120
0
1920
0
2560
0
3840
0
2560
0
1920
0
5120
0
3840
0
5120
0
1920
0
2560
0
3840
0
2560
0
1920
0
5120
0
3840
0
5120
0
1920
0
2560
0
3840
0
2560
0
1920
0
FVAL Active (A)
DVAL Active (A)
(E) Exposure time (Max)
(E) Exposure time (Max)
(A)
Binning
1:OFF, 2:ON
FVAL
Active
[Unit: Line]
3840
1
1
1920
1
2
3840
2
1
1920
2
2
3840
1
1
1920
1
2
3840
2
1
1920
2
2
3840
1
1
1920
1
2
3840
2
1
1920
2
2
- 30 -
(B)
(B)
0 Line
0 Line
(B)
(C)
FVAL
Exposure
Non
V -Offset
-Active
[Unit:
[Unit: Line]
[Unit: us]
Line]
321.1
160.6
0
321.1
160.6
320.6
160.3
0
320.6
160.3
320.6
160.3
0
320.6
160.3
(D)
Time
(Min)
10.0
10.0
10.0