IAI SP-20000M-CXP2 User Manual page 65

20 mp cmos digital progressive scan monochrome and color camera spark series
Hide thumbs Also See for SP-20000M-CXP2:
Table of Contents

Advertisement

SP-20000M-CXP2 / SP-20000C-CXP2
Set Offset X of sequence ROI.
Sequence ROI Binning Horizontal =1 (Off):
Setting range is 0 to (5120 - [Sequence ROI Width])
Sequence ROI Binning Horizontal =2 (On):
Setting range is 0 to (2560 - [Sequence ROI Width])
The limitations of step number and other factors are the same as the normal ROI mode set by
[Video Send Mode] ="Normal".
(5) Sequence ROI Offset Y
Set Offset Y of sequence ROI.
Sequence ROI Binning Vertical =1 (Off):
Setting range is 0 to (3840 - [Sequence ROI Height])
Sequence ROI Binning Vertical =2 (On):
Setting range is 0 to (1920 - [Sequence ROI Height])
The limitations of step number and other factors are the same as the normal ROI mode set by
[Video Send Mode] ="Normal".
(6) Sequence ROI Gain Selector
In Sequence ROI Gain Selector, the gain settings for each index are available.
SP-20000C-CXP2: Gain (ALL), Red, and Blue can be set.
SP-20000M-CXP2: Only Gain is displayed and can be set.
(7) Sequence ROI Black Level
Black Level setting is available for each index.
(8) Sequence ROI Exposure Time
Exposure Time setting is available for each index.
(9) Sequence ROI Binning Horizontal
ON or OFF of Horizontal Binning for each index can be set.
(10) Sequence ROI Binning Vertical
ON or OFF of Vertical Binning for each index can be set.
(11) Sequence ROI LUT Enable
Enable or disable of LUT function for each index 0 to 9 can be set.
(12) Sequence ROI Frame Count
This can set how many times the seleted index is repeated. This is applied to each index.
Triggers are input according to numbers set in Frame Count and index is repeated and moves
to the next index. Therefore, the same number of triggers as Frame Count must be input.
(13) Sequence ROI Next Index
Only when Trigger Sequence is configured, it is possible to set the next index to the
currently executing index. In this case, after the aquisition starts and the external trigger
is input, the index table always starts from index 0. Accordingly, after the repeated
cycle of index 0 set by Frame Count is completed, the next index can be set as required.
However, if Sequence ROI Next Index is set to OFF, it refers to the setting of Sequence
Repetition.