Hitachi G900 Hardware Reference Manual

Hitachi G900 Hardware Reference Manual

Virtual storage platform
Hide thumbs Also See for G900:
Table of Contents

Advertisement

Hitachi Virtual Storage Platform G900
88-01-0x
Hardware Reference Guide
This document provides information about the system hardware components and the mechanical and
environmental specifications for the Hitachi Virtual Storage Platform G900 storage system.
MK-97HM85014-00
May 2018

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi G900

  • Page 1 Hitachi Virtual Storage Platform G900 88-01-0x Hardware Reference Guide This document provides information about the system hardware components and the mechanical and environmental specifications for the Hitachi Virtual Storage Platform G900 storage system. MK-97HM85014-00 May 2018...
  • Page 2 Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    16-Gbps Fibre Channel (2-port) board LEDs and connectors....24 PCIe module................... 25 LAN blade LEDs and connectors..............27 Back-end module LEDs and connectors............27 Chapter 3: Drive trays................29 Small form-factor drive tray (DBS)..............29 SFF with front panel bezel................29 Contents Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 4 Appendix A: Storage system parts list..........56 VSP G900 parts list....................56 Drive tray and drive configuration..............61 Data and power cable model list................62 Appendix B: System Specifications ...........65 VSP G900 mechanical specifications..............65 Contents Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 5 AC connections..................105 Power cable usage guidelines..............107 Three-phase power considerations for racks..........107 Cable management..................107 Appendix E: Power distribution units for Hitachi Universal V2 Rack .....................108 Americas single-phase PDU 1P30A-8C13-3C19UL.P........108 Americas single-phase PDU 1P30A-15C13-3C19UL.P........109 Americas three-phase PDU 3P30A-8C13-3C19UL.P........109 Americas three-phase PDU 3P30A-15C13-3C19UL.P........
  • Page 6 Dense intermix drive tray power supply............127 CMA (used to secure dense intermix drive tray)..........128 Battery......................128 Host port expansion chassis................128 PCIe switch board....................129 Appendix H: Environmental notices..........131 Appendix I: Regulatory compliance..........132 Contents Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 7: Preface

    Preface This guide describes the hardware features and specifications of the Hitachi Virtual Storage Platform G900. Intended audience This document is intended for system administrators, Hitachi Vantara representatives, and authorized service providers who install, configure, and operate the VSP Gx00 models.
  • Page 8: Product Version

    ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Product version This document revision applies to VSP G900 firmware 88-01-0x or later. Release notes Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document.
  • Page 9 { a | b } indicates that you must choose either a or b. This document uses the following icons to draw attention to information: Icon Label Description Note Calls attention to important or additional information. Preface Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 10: Conventions For Storage Capacity Values

    Logical capacity unit Value 1 block 512 bytes 1 cylinder Mainframe: 870 KB Open-systems: OPEN-V: 960 KB ■ Others: 720 KB ■ 1 KB 1,024 (2 ) bytes Preface Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 11: Accessing Product Documentation

    Getting help Hitachi Vantara Support Connect is the destination for technical support of products and solutions sold by Hitachi Vantara. To contact technical support, log on to Hitachi Vantara Support Connect for contact information: https://support.hitachivantara.com/en_us/ contact-us.html. Hitachi Vantara Community is a global online community for Hitachi Vantara customers, partners, independent software vendors, employees, and prospects.
  • Page 12: Chapter 1: Overview

    Chapter 1: Overview The Hitachi Virtual Storage Platform G900 is a versatile modular, rack-mountable hybrid array storage system equipped with drive boxes, supporting SAS drives, flash drives, and TLC-NAND flash module drives, scaled for various storage capacity configurations. The storage systems provide high performance operations by using dual controllers with high-speed processors, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, fans and ports to connect iSCSI and Fibre Channel I/O modules.
  • Page 13 Flash drive tray (DBF): Up to 12 flash module drives (FMD) can be installed (2U size) ■ Supports system environments with mixed operating systems such as UNIX, Linux, ■ Windows, and VMware Chapter 1: Overview Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 14: Chapter 2: System Controller

    Each controller includes the following internal components such as a processor, dual in- line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out-of-band management using Hitachi Device Manager - Storage Navigator. If the data path through one controller fails, all drives remain available to data hosts using a redundant data path through the other controller.
  • Page 15 ALARM LED Off: Normal operation. Red: Processor failure (system might be down). For assistance, contact customer support: https:// support.hitachivantara.com /en_us/contact-us.html. POWER ON/OFF (main Powers the storage system. switch) Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 16: Cbl Controller Front Panel Leds (Without Bezel)

    (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. Controllers Controller 1 (bottom) and Controller 2 (top). Backup module Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 17 Blink red one time: Main battery failure. Blink red two times: Backup battery failure. Blink red three times: Both batteries failed or preventive maintenance replacement of batteries can run. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 18: Cbl Controller Rear Panel Leds

    Back end module LAN blade CBL controller power supply unit LEDs and connectors The following table lists the definitions of the CBL controller power supply unit LEDs and connectors. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 19: Host, Network, And Drive Tray Ports And Leds

    Front end modules The following front end modules are available for the controllers. The LEDs display the operating status of the module. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 20: 10-Gbps Iscsi Board Leds And Connectors (Optical)

    Blue: Normal link status. Blink blue: Front end module is in communication status. iSCSI connectors Connect to Ethernet cables. 10-Gbps iSCSI board LEDs and connectors (copper) Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 21 Off: No link connection. PORT LED Green: Link connection is established. Blinking: Communication is in progress. Off: No link connection or not ready to communicate. iSCSI connectors Connect to Ethernet cables. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 22: 8-Gbps, 16-Gbps, Or 32-Gbps Fibre Channel (4-Port) Board Leds And Connectors

    Item Description Fibre Channel connectors Connect to Fibre Channel cables. STATUS LED Green: Front end module is in power-on state. Red: Front end module can be removed safely. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 23 8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel ports (left to right) CHB number Port 1 Port 2 Port 3 Port 4 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 24: 16-Gbps Fibre Channel (2-Port) Board Leds And Connectors

    Red: Small form factor pluggable can be removed. Blue: Normal link status at 16-Gbps. Green: Normal link status at 4-Gbps or 8-Gbps. Fibre Channel connectors Connect to Fibre Channel cables. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 25: Pcie Module

    16-Gbps Fibre Channel ports (left to right) CHB number Port 1 Port 2 CHB-1A CHB-1B CHB-1C CHB-1D CHB-1E CHB-1F CHB-1G CHB-1H CHB-2A CHB-2B CHB-2C CHB-2D CHB-2E CHB-2F CHB-2G CHB-2H PCIe module Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 26 Gbps) and is linked up normally. Off: PCIe is not linked up (PCIe cable might not be connected). If a PCIe cable is connected, it can be removed safely. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 27: Lan Blade Leds And Connectors

    LAN ALARM LED Red: LAN blade can be removed. Uninterruptible power supply (UPS) port Back-end module LEDs and connectors The back-end module LEDs display the operating status of the module. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 28 Red: Back end module can be removed safely. PORT LED Blue: Link status is normal. PATH 0 connector Connect to a drive tray. PATH 1 connector Connects to a drive tray. Chapter 2: System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 29: Chapter 3: Drive Trays

    2U (88.2 mm) 2.5 inch (SFF) SFF with front panel bezel Number Item Description POWER LED Green: Drive tray is powered on. READY LED Green: Drive tray is operational. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 30: Sff Front Panel Without Bezel

    Blink green: Drive is being accessed. ALM LED Red: Drive stopped due to a failure and can be replaced. POWER, READY, and Green: Drive tray is LOCATE LEDs powered on. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 31: Sff Rear Panel

    Green: ENC is in the power- on state. Locate LED Amber: Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 32: Ac Power Supply Unit Leds And Connectors

    Both SFF and LFF drive trays are equipped with AC power supply units. The AC power supply units include LEDs to display its operating status. Number Item Description RDY LED Green: Normal operation. AC IN LED Green: AC input is operating normally. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 33: Large Form-Factor Drive Tray (Dbl)

    ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 34: Lff Front Panel Without Bezel

    Large form factor drives The twelve 3.5-inch large form factor drives are positioned horizontally. The slots are organized in the following order: Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 35: Lff Rear Panel

    Connects to the power cable provided with the storage system. AC IN LED Green: Normal operation. ALM LED Red: Power supply unit can be replaced. RDY LED Green: Normal operation. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 36: Ac Power Supply Unit Leds And Connectors

    The following describes the physical specifications of the flash module drive tray. Number of Name Model name Height drive slots Drive type DW-F800-DBF 2U (87 mm) Flash module drive (FMD) FMD with front panel bezel Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 37: Fmd Front Panel Without Bezel

    Locks and unlocks the front panel bezel by using the supplied key. FMD front panel without bezel Number Item Description 1, 2 ACT LED Green: Normal operation. Blink: Drive is being accessed. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 38 Flash module drives Twelve flash module drives. Slots are organized the following way: 9, 10, 11 6, 7, 8 3, 4, 5 0, 1, 2 Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 39: Fmd Rear Panel

    Receptacle Connects to the power cable provided with the storage system. Three LEDS, top to bottom: Green: Power supply unit is operating normally. RDY LED AC IN LED Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 40: High-Density Intermix Drive Tray (Db60)

    3.5 inch (LFF) DB60C Dense intermix drive tray with front panel bezel Number Item Description POWER LED Green: Drive tray is powered on. READY LED Green: Drive tray is operational. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 41: Dense Intermix Drive Tray Display Leds

    Dense intermix drive tray display LEDs Number Item Description Green: Normal operation. Blink green: Drive is being accessed. ALM LED Red: Drive stopped due to a failure and can be replaced. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 42: Dense Intermix Drive Tray Rear Panel

    Connects to the power cable provided with the storage system. PATH (OUT) LED Blue: OUT side port is linked up. PATH (OUT) connector Connect to a drive tray. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 43 Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. POWER LED Green: ENC is in the power- on state. Chapter 3: Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 44: Chapter 4: Host Port Expansion Chassis

    Green: Host port expansion is turned on. Amber: PCIe module is turned on. Off: PCIe module is turned off. Safety lock Lock or unlock the front bezel. PCIe switchboard Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 45: Host Port Expansion Chassis Fan

    STATUS LED Green: PCIe switchboard is powered on. Red: PCIe switchboard can be replaced safely. Off: PCIe switchboard is powered off. Host port expansion chassis fan Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 46: Pcie Cable Connector

    PCIe cable connector Number Item Description ALM LED Red: Fan failure has occurred. Off: Normal operation. PCIe cable connector Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 47: Host Port Expansion Chassis Power Supply

    Cables can be removed safely. Off: Option PCIe is normal or not set. Host port expansion chassis power supply Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 48 ALM / RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. AC IN LED Blue: AC input is normal. Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 49: Chapter 5: Service Processor

    The SVP is also available as a 64-bit software application provided by Hitachi Vantara. For the latest interoperability updates and details, see the SVP (Service Processor) OS and Hypervisor support for Gx00, Fx00 report at https://support.hitachivantara.com/en_us/...
  • Page 50: Service Processor Description

    <model number><system serial number>/emergency.do. For example: Storage system model Storage system serial number number 8320004 456789 http://192.168.0.15/dev/ storage/8320004456789/ emergency.do 8340004 456789 http://192.168.0.15/dev/ storage/8340004456789/ emergency.do 8360004 456789 http://192.168.0.15/dev/ storage/8360004456789/ emergency.do Chapter 5: Service processor Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 51: Svp Front Panel

    Turning on automatic Windows updates or using the manual Windows update ■ method. Installing antivirus software that has been tested and approved by Hitachi. ■ SVP front panel The front panel of the physical SVP with Windows 10 Enterprise operating system is equipped with LEDs, a reset button, and a power button.
  • Page 52 Note: After the Initial Startup Wizard is complete, the SVP can be used in non- bridge mode. In this mode, the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches. For more information, contact customer support. Chapter 5: Service processor Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 53: Chapter 6: Maintaining The Storage System

    To avoid this situation, charge the battery for more than three hours at least once every six months. Chapter 6: Maintaining the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 54: Battery Unit

    Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). Chapter 6: Maintaining the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 55 SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Chapter 6: Maintaining the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 56: Appendix A: Storage System Parts List

    Appendix A: Storage system parts list The following parts list describes the standard and optional hardware components for the storage systems. For more information about the storage system, contact an Hitachi Vantara sales representative. VSP G900 parts list The VSP G900 includes the following standard and optional components.
  • Page 57 SFP for 32 Gbps Longwave 0-80 DW-F800-BAT Battery Note: 1. A DIMM of a particular capacity cannot be mixed with different capacities in a storage system configuration. Appendix A: Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 58 Table 9 DBL drive box components Model number Part description Quantity DW-F800-DBLC 2U chassis AC power supply unit Front bezel (2U) DW-F800-RRDB Rail kit Appendix A: Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 59 3.5 TB, MLC 12 Gbps, flash 0-12 module drive DKC-F810I-7R0FP 7 TB, MLC/TLC 12 Gbps, 0-12 flash module drive DKC-F810I-14RFP 14 TB, MLC/TLC 12 Gbps, 0-12 flash module drive Appendix A: Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 60 2.4 TB, 2.5-inch, 10kmin, 12 0-60 Gbps, SAS, drive DKC-F810I-6R0HLM 6 TB, 3.5-inch, 7.2kmin, 12 0-60 Gbps, SAS, drive DKC-F810I-10RHLM 10 TB, 3.5-inch, 7.2kmin, 12 0-60 Gbps, SAS, drive Appendix A: Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 61: Drive Tray And Drive Configuration

    Number of mountable drive trays Maximum number of mountable drives Flash Controller Solid-state module chassis Drive trays Maximum SAS drive drive drive (FMD) 1,152 1,152 DB60 1440 1,200 Appendix A: Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 62: Data And Power Cable Model List

    5 m SAS cable, including omega clips (2) DW-F800-SCQ10A 10 m SAS optical cable DW-F800-SCQ30A 30 m SAS optical cable DW-F800-SCQ1HA 100 m SAS optical cable Appendix A: Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 63 30 m LC-LC optical cable for optical A-6515-JM50L 50 m LC-LC optical cable for optical A-6515-JM100L 100 m LC-LC optical cable for optical A-6515-JM200L 200 m LC-LC optical cable for optical Appendix A: Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 64 Data and power cable model list Model number Specification A-6515-JM300L 300 m LC-LC optical cable for optical Appendix A: Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 65: Appendix B: System Specifications

    Appendix B: System Specifications The storage system mechanical, electrical, and environmental specifications are listed. VSP G900 mechanical specifications The following tables list the system specifications for VSP G900. CBL controller chassis Item Specification Physical dimension 483 × 808.1 × 174.3 mm...
  • Page 66 DB60 184 W Power 126 VA consumption (VA) 144 VA 130 VA DB60 191 VA Air flow (m /min) 2.2 (m /min) 2.2 (m /min) 1.6 (m /min) Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 67 472.61, 945.23, 1890.46, 3780.92, 7561.85 GB transfer speed (12 Gbps SSD) 576.39, 1152.79, 1729.29, 2305.58 GB (10K RPM HDD) 5874.22, 9790.36 GB (7.2K RPM HDD) DB60 1152.79, 1729.29, 2305.58 GB (10K RPM HDD) Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 68 1000 Mbps (iSCSI - Copper) Number of ports 16/32 Gbps FC (Optical): 64 10 Gbps iSCSI (Optical): 32 10 Gbps iSCSI (Copper): 32 Number of ports 16/32 Gbps FC (Optical): 80 Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 69 4 years Up to 104º (40º C) 3 years RAID specifications Item Specification RAID level SAS/SAS7.2K/Flash drive mounted: 1/5/6 RAID configuration RAID1: 2D+2D, 4D+4D RAID5: 3D+1P, 4D+1P, 6D+1P, 7D+1P Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 70 Flash memory: 32 MB L3 cache memory: 4 MB SDRAM: 1 GB Data assurance method Data bus: Parity Cache memory: ECC (1 bit correction, 2 bit detection) Drive: Data assurance code Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 71: Electrical Specifications

    Number of phases, cabling Single-phase with protective grounding Steady-state current 100V/ CBL: 4.0x2 SFF drive tray: 2.4x2/1.2x2 200V LFF drive tray: 1.9x2/1.0x2 FMD tray: 2.6x2/1.3x2 Dense intermix drive tray: -/3.0x2 Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 72: Environmental Specifications

    . The actual required power might exceed the value shown in the table when the tolerance is included. Environmental specifications The environmental specifications for the storage systems are described in the following table. Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 73 14°F to 95°F (-10°C to 35°C) (-10°C to 50°C) Transport, -22°F to 140°F -22°F to 122°F (-30°C to 50°C) storage (-30°C to 60°C) Temperature 10°C or less change rate (°C/h) Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 74 CBL controller and drive trays Operating 20 or less (m/s (10 ms, half sine wave) Non-operating 50 or less (m/s (10 ms, half sine wave) Transport (packed) 80 or less Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 75 40ºC at an altitude of 950m (3000 feet) to 28ºC at an altitude of 3050m (1000 feet). The allowable ambient temperature is decreased by 1ºC for every 175m increase in altitude above 950m. Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 76 Operating Gaseous contamination should be within ANSI/ISA S71.04-2013 G1 classification levels. Non-operating Recommends the data centers maintain a clean operating environment by monitoring and controlling gaseous contamination. Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 77 Therefore, the rate of the noise occupied by high-frequency content is high. Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 78 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. 4. When accessing the dense intermix drive tray, do not work for long times at the rear of the rack. Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 79 The acoustic noise level of 90 dB or less in the operating environment table represents the current operating environment guidelines in which Hitachi storage systems are designed and manufactured for reliable operation when placed 2 meters from the source of the noise.
  • Page 80 Environmental specifications State Condition Hitachi does not test storage systems and data drives (includes HDDs, SSDs, and FMDs) for compatibility with fire suppression systems and pneumatic sirens. Hitachi also does not provide recommendations or claim compatibility with any fire suppression systems and pneumatic sirens.
  • Page 81: Shared Memory

    Storage applications may require a license before they can be used. Note: Volume Migration is included in Hitachi Tiered Storage Manager. Table 20 Reference table of shared memory capacity (VSP G900) 1, 2 Factors affecting shared memory (SM) capacity...
  • Page 82 User Guide for the number of pairs that can be created ® by TrueCopy. Refer to Hitachi Universal Replicator User Guide for the number of pairs that can be created by TrueCopy. The following table shows the usable capacity of the pool or virtual volume.
  • Page 83 If the capacity of a pool/virtual volume exceeds 0.2 PB , use Extension. When changing Extension to unused, delete all the Dynamic Provisioning, Dynamic Tiering, active flash, and Thin Image pools. Appendix B: System Specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 84: Appendix C: Network Access

    Review the following ports before you install the storage system to avoid conflicts between the TCP/IP port assignments used by the storage system and those used by other devices and applications. Appendix C: Network access Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 85 TCP/IP port assignments Port number Usage description Used by the SVP, Hitachi Storage Advisor, and Device Manager - Storage Navigatorto communicate through the HTTP protocol. UDP (SNMP uses this port to send traps from the storage system) . Used by SMI-S.
  • Page 86 S is not used. or later Automatic 88-01-0x -xx/00 allocation or later CommonJettySt HTTP 8080 88-01-0x -xx/00 or later CommonJettySt HTTP 8210 RestAPIServerS HTTP 9210 DeviceJettyStart HTTP 8081 Appendix C: Network access Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 87: Controller Connections

    ■ Physical service processor connections The SVP is available as an optional, physical device provided by Hitachi Vantara or as a virtual guest host running on customer-provided ESX servers and VM/OS licenses and media. The SVP provides error detection and reporting and supports diagnostic and maintenance activities involving the storage system.
  • Page 88 ■ SVP Guest OS (1 DKC) Windows 10 Enterprise ■ 2 x vCPU ■ 1 virtual network adapter ■ 4 GB RAM ■ 120 GB disk space ■ Appendix C: Network access Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 89: Appendix D: Data And Power Cables

    Serial-attached SCSI (SAS) cables are used to connect drive trays to controllers and other drive trays. Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 90 Fibre Channel cable length based on cable size and port speed. Cable size Speed Maximum cable length 9 micron 1 Gbps 1 km (3281 ft) 2 Gbps 2 km Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 91: Fibre Channel Cables

    Note: Due to high-speed serial data transfer via Fibre Channel, use high- quality FC cables that comply with the Fibre Channel-PH standard. The following figure shows FC direct connection and FC connection through a switch. Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 92 114.8 ft (35 m) 328.08 ft (100 410.1 ft (125 m) — 32 Gbps 65.62 ft (20 m) 229.7 ft (70 m) 328.08 ft (100 — Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 93 Wavelength: (OMx) 850 nm LC-LC cable DXLC-2PS- 9/125 μm (longwave) SPC-xxM- Singlemode Wavelength: 10/125-2SR 1300 nm The following figure shows the connector used for optical interfaces. Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 94: Iscsi Cables

    Interface name Cable One side Other side LC-LC cable Optical Equivalent 50, 125 mm to DXLC-2P- Multimode connector connector PC-xxM- Wavelength: GC50, 850 nm 125-2SR (OMx) Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 95 LC connector type ■ Connector type: LC duplex receptacle connector ■ Interval: 6.25 mm flat type, two rows ■ Cable specifications for 10 Gbps iSCSI copper interface Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 96 50 m 10 Gbps 10GBASE-T STP ( use an RJ-45 LAN cable STP cable that suppresses radio noise) The following figure shows a 10 Gbps iSCSI cable. Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 97: Iscsi Standards

    255 (maximum per iSCSI With Linux software port) initiator, the maximum number decreases. Path failover HDLM Supports Microsoft MPIO (Multi Path I/O) Link 10 Gbps SFP+ Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 98 When an iSCSI Port IPv6 is set to Enabled, verify the IPv6 router is connected to the same network, and then set IPv6 global address automatically. Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 99 Header digest Supported Detects header error or data error with iSCSI communication. The storage system follows the host's digest setting. If digest is enabled, the performance degrades. Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 100: Managing Cables

    ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef Managing cables Organize cables to protect the integrity of your connections and allow proper airflow around your storage system. Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 101 Fibre Channel 40 mm (1.73 inch) iSCSI optical 40 mm (1.73 inch) Category 5 Ethernet Four times the outside diameter of the cable 40 mm (1.73 inch) Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 102 Cabling full-width modules When cabling full-width modules, route the cables horizontally, so that they do not interfere when replacing a module. Ensuring adequate airflow Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 103: Ac Power Cables

    ■ AC power cables Utility AC power standards for connector types and voltage levels vary by country. Hitachi provides a variety of power cables that facilitate using storage systems around the world. Hitachi power cables meet the safety standards for the country for which they are intended.
  • Page 104 South Africa 200-240 10, 16 SABS-164 Switzerland 200-240 SEV 1011 International 200-240 IEC 309 United 200-240 BS-1363 Kingdom International 200-240 IEC 309 International 200-240 IEC 309 Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 105: Ac Connections

    3 IEC 83 NEMA L6-20P 200V-240V 1 ANSI C73.11 2 NEMA 6-15P 3 IEC 83 CEE 7/7 200V-240V 4 CEE (7) II, IV, VII 3 IEC 83 Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 106 AC connections Reference Description Receptacle Input rating standards BS-1363 200V-240V 5 BS 1365 3 IEC 83 AS-3112 200V-240V 6 AS C112 Cable and connector Appendix D: Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 107: Power Cable Usage Guidelines

    Power cable usage guidelines Power cable usage guidelines Hitachi storage systems are intended for rack installation and ship with power cords. Installation and service requirements may require additional cords and cables to be ordered. The type of power cable required by a given installation is determined primarily by the: Type of AC line feed provided by the facility.
  • Page 108: Appendix E: Power Distribution Units For Hitachi Universal V2 Rack

    Appendix E: Power distribution units for Hitachi Universal V2 Rack The Hitachi Universal V2 Rack is equipped with specific power distribution units (PDU) for Americas, APAC, and EMEA regions. The PDUs can provide electrical power to the storage system in a single-phase or three-phase configuration.
  • Page 109: Americas Single-Phase Pdu 1P30A-15C13-3C19Ul.p

    Americas single-phase PDU 1P30A-15C13-3C19UL.P Americas single-phase PDU 1P30A-15C13-3C19UL.P The following figure and table describes the specifications of the PDU. Figure 2 Americas PDU for the Hitachi Universal V2 Rack (Single-phase PDU 1P30A-15C13-3C19UL.P) Part Number Region Phase Description 1P30A-15C13-3C19 Americas Single 208V, 30A (24A ■...
  • Page 110: Americas Three-Phase Pdu 3P30A-15C13-3C19Ul.p

    Americas three-phase PDU 3P30A-15C13-3C19UL.P Figure 3 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-8C13-3C19UL.P) Part Number Region Phase Description 3P30A-8C13-3C19U Americas Three 208V 3P, 30A ■ (24A rated) 60Hz 8 IEC C13 + 3 IEC ■ C19 sockets NEMA L15-30P ■...
  • Page 111: Americas Three-Phase Pdu 3P30A-24C13-6C19Ul.p

    Americas three-phase PDU 3P30A-24C13-6C19UL.P Figure 4 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-15C13-3C19UL.P) Part Number Region Phase Description 3P30A-15C13-3C19 Americas Three 208V 3P, 30A ■ UL.P (24A rated) 60Hz 15 IEC C13 + 3 ■ IEC C19 sockets NEMA L15-30P ■...
  • Page 112: Apac And Emea Single-Phase Pdu 1P32A-9C13-3C19Ce.p

    APAC and EMEA single-phase PDU 1P32A-9C13-3C19CE.P Figure 5 Americas PDU for the Hitachi Universal V2 Rack (Three-phase PDU 3P30A-24C13-6C19UL.P) Part Number Region Phase Description 3P30A-24C13-6C19 Americas Three 208V 3P, 30A ■ UL.P (24A rated) 60Hz 24 IEC C13 + 6 ■...
  • Page 113: Apac And Emea Single-Phase Pdu 1P32A-18C13-3C19Ce.p

    APAC and EMEA single-phase PDU 1P32A-18C13-3C19CE.P Figure 6 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Single-phase 1P32A-9C13-3C19CE.P) Part Number Region Phase Description 1P32A-9C13-3C19C APAC and EMEA Single 230V max. 32A ■ 50Hz / 60Hz 9 IEC C13 + 3 IEC ■...
  • Page 114: Apac And Emea Three-Phase Pdu 3P16A-9C13-3C19Ce.p

    APAC and EMEA three-phase PDU 3P16A-9C13-3C19CE.P Figure 7 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Single-phase 1P32A-18C13-3C19CE.P) Part Number Region Phase Description 1P32A-18C13-3C19 APAC and EMEA Single 230V max. 32A ■ CE.P 50Hz / 60Hz 18 IEC C13 + 3 ■...
  • Page 115: Apac And Emea Three-Phase Pdu 3P16A-15C13-3C19Ce.p

    APAC and EMEA three-phase PDU 3P16A-15C13-3C19CE.P Figure 8 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three-phase 3P16A-9C13-3C19CE.P) Part Number Region Phase Description 3P16A-9C13-3C19C APAC and EMEA Three 400V max. 3x ■ 16A 50Hz / 60Hz 9 IEC C13 + 3 IEC ■...
  • Page 116: Apac And Emea Three-Phase Pdu 3P32A-24C13-6C19Ce.p

    APAC and EMEA three-phase PDU 3P32A-24C13-6C19CE.P Figure 9 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three-phase 3P16A-15C13-3C19CE.P) Part Number Region Phase Description 3P16A-15C13-3C19 APAC and EMEA Three 400V max. 3x ■ CE.P 16A 50Hz / 60Hz 15 IEC C13 + 3 ■...
  • Page 117 APAC and EMEA three-phase PDU 3P32A-24C13-6C19CE.P Figure 10 APAC and EMEA PDU for the Hitachi Universal V2 Rack (Three-phase 3P32A-24C13-6C19CE.P) Part Number Region Phase Description 3P32A-24C13-6C19 APAC and EMEA Three 400V max. 3x ■ CE.P 32A 50Hz / 60Hz 24 IEC C13 + 6 ■...
  • Page 118: Appendix F: Non-Hitachi Racks

    PDUs and cable loops. Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack. The following tables list the rail kit information for the specified storage systems.
  • Page 119: Hitachi Universal V2 Rack Accessories

    2. CGR: Corner guide rail kit A3BF-HK-GL-740-1. Hitachi Universal V2 Rack accessories The following table provides rack accessory information for VSP G series storage systems. Table 23 Accessories for the Hitachi Universal V2 Rack Storage system Front door Rear door...
  • Page 120 Third-party rack support for DB60 dense intermix drive trays Appendix F: Non-Hitachi racks Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 121: Appendix G: Warning Labels On The Storage System

    Use caution when handling equipment with movable parts. Use caution when handling equipment with hot surfaces. Use caution when handling equipment prone to tipping over. Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 122: Cbl Controller

    CBL controller CBL controller Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 123: Small Form Factor Drive Tray

    Small form factor drive tray Small form factor drive tray Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 124: Large Form Factor Drive Tray

    Large form factor drive tray Large form factor drive tray Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 125: Flash Module Drive Tray

    Flash module drive tray Flash module drive tray Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 126: Dense Intermix Drive Tray

    Dense intermix drive tray Dense intermix drive tray Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 127: Cbl Controller

    CBL controller CBL controller Dense intermix drive tray power supply Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 128: Cma (Used To Secure Dense Intermix Drive Tray)

    CMA (used to secure dense intermix drive tray) CMA (used to secure dense intermix drive tray) Battery Host port expansion chassis Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 129: Pcie Switch Board

    PCIe switch board PCIe switch board Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 130 PCIe switch board Appendix G: Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 131: Appendix H: Environmental Notices

    They will dispose of it for you. This nickel-metal hydride battery, which is designated as recycling product by a recycling promotion low, must be recycled. The mark posted on the Cache Backup Battery is a three-arrow mark that indicates a recyclable part. Appendix H: Environmental notices Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 132: Appendix I: Regulatory Compliance

    Appendix I: Regulatory compliance This equipment has been tested and certified for compliance with the following standards. Appendix I: Regulatory compliance Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 133 All CB countries 1+A2 IEC60950-1:2005+A S_Mark Argentina 1+A2 TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan EN60950-1:2006+A1 CE marking 1+A1+A12+A2 Radio interference VCCI V-3/2015.4 VCCI Japan voluntary control Appendix I: Regulatory compliance Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 134 This is a class A product. In a domestic environment this product can cause radio interference in which case the user can be required to take adequate measures. Appendix I: Regulatory compliance Hitachi Virtual Storage Platform G900 Hardware Reference Guide...
  • Page 135 Hitachi Vantara Corporation Corporate Headquarters Regional Contact Information 2845 Lafayette Street Americas: +1 866 374 5822 or info@hitachivantara.com Santa Clara, CA 95050-2639 USA Europe, Middle East, and Africa: +44 (0) 1753 618000 or info@emea@hitachivantara.com www.HitachiVantara.com | community.HitachiVantara.com Asia Pacific: + 852 3189 7900 or info.marketing.apac@hitachivantara.com...