VTI Instruments Corp.
API
vtex10xxA_set_arm_lan_filter
vtex10xxA_set_arm_source
vtex10xxA_set_arm_sourceEx
vtex10xxA_set_channel_conversion
vtex10xxA_set_channel_range
vtex10xxA_set_communication_timeout
Function Prototype
V
S
I
TATUS
10
A_
_
VTEX
XX
SET
COMMUNICATION
V
I
32
);
I
NT
TIMEOUT
Function Parameters
vi = contains a session handle to the instrument. This handle is
obtained by the function and remains valid until the session is
closed.
SETS THE TIMEOUT VALUE (IN MILLISECONDS).
INDICATING HOW LONG TO WAIT FOR INSTRUMENT
TO RESPOND. IN HIGHER LATENCY NETWORK, IT IS
BETTER NOT TO REDUCE DEFAULT TIMEOUT VALUE.
VALID RETURN VALUES: 1000 THROUGH (231-1).
DEFAULT VALUE: 25000 (25 SECONDS).
D
I
R
V
ATA
TEM
ESET
ALUE
Reset will not change value of this parameter.
Description
This function sets the timeout value when a LAN communication
error occurs. It is recommended for advanced users only.
Example
//sets the LAN communication timeout to 10 seconds, if a LAN
communication error occurs
vtex10xxA_set_communication_timeout(vi, 10000);
vtex10xxA_set_dio_limit_event
vtex10xxA_set_dio_limit_event_invert
vtex10xxA_set_dio_limit_event_latch
vtex10xxA_set_dio_output
vtex10xxA_set_dio_output_enable
vtex10xxA_set_dio_pulse
vtex10xxA_set_fifo_config
vtex10xxA_set_filt_freq
vtex10xxA_set_init_cont
vtex10xxA_set_lan_event_domain
vtex10xxA_set_lan_eventlog_enabled
vtex10xxA_set_lan_eventlog_overflowmode
vtex10xxA_set_limit_set0
vtex10xxA_set_limit_set0_manual
128
_VI_FUNC
_
(V
S
TIMEOUT
I
ESSION VI
Description
Sets the filter for the LAN arm event.
Sets the arm source. Excludes LAN events.
Sets the arm source. Includes LAN events.
Sets the engineering units (EU) conversion for the
specified channels.
Sets the input range of a voltage channel.
Links limit evaluations to the operation of the
digital I/O port.
,
Enables or disables inverted operation of a DIO
channel linked as a limit event.
Enables or disables latch operation of a DIO
channel linked as a limit event.
Sets the static level that each channel of the digital
I/O port will assume if enabled.
Enables or /disables the output functionality of
each channel of the digital I/O port.
Generates a 1 µs pulse on selected channels of the
digital I/O port.
Sets the data format and overflow behavior of the
FIFO memory.
Sets low-pass filter cutoff frequency of specified
channels.
Enables or disables the use of init continuous
mode.
Sets the instrument's LAN domain.
Enables/disables the event log.
Sets the LAN event log overflow mode.
Sets the limit set 0 values manually for the
specified channels.
Enables or disables manual entry of limit set 0
values for the specified channels.
EX10xxA Function Calls
Need help?
Do you have a question about the EX1000A and is the answer not in the manual?