MEDICAL DEVICE / PACEMAKER DANGER: Magnetic and electromagnetic fields in the
vicinity of current carrying conductors and industrial motors can result in a serious health
hazard to persons with cardiac pacemakers, internal cardiac defibrillators, neurostimulators,
WARNING
metal implants, cochlear implants, hearing aids, and other medical devices. To avoid risk,
stay away from the area surrounding a motor and its current carrying conductors.
Be sure all wiring complies with the National Electrical Code and all regional and local
codes. Improper wiring may result in unsafe conditions.
CAUTION
The stop input to this equipment should not be used as the single means of achieving a
safety critical stop. Drive disable, motor disconnect, motor brake and other means should
be used as appropriate.
CAUTION
Improper operation or programming of the drive may cause violent motion of the motor and
driven equipment. Be certain that unexpected motor movement will not cause injury to
personnel or damage to equipment. Peak torque of several times the rated motor torque
CAUTION
can occur during control failure.
If the drive enable signal is already present when power is applied to the MicroFlex e100, the
motor could begin to move immediately.
CAUTION
The metal heatsink on the left side of the MicroFlex e100 can become very hot during
normal operation.
CAUTION
When operating a rotary motor with no load coupled to its shaft, remove the shaft key to
prevent it flying out when the shaft rotates.
NOTICE
A regeneration resistor may generate enough heat to ignite combustible materials.
To avoid fire hazard, keep all combustible materials and flammable vapors away from the
brake resistors. Baldor regeneration resistors are neither internally fused nor thermally
NOTICE
protected and under extreme conditions, can cause a fire hazard if not suitably protected or
rated for the application
To prevent equipment damage, be certain that the input power has correctly sized protective
devices installed.
NOTICE
To ensure reliable performance of this equipment be certain that all signals to/from the drive
are shielded correctly.
NOTICE
Suitable for use on a circuit capable of delivering not more than the RMS symmetrical short
circuit amperes listed here, at the rated maximum voltage:
Horsepower
NOTICE
1-50
Avoid locating the drive immediately above or beside heat generating equipment, or directly
below water or steam pipes.
NOTICE
Avoid locating the drive in the vicinity of corrosive substances or vapors, metal particles and
dust.
NOTICE
MN1942
RMS Symmetrical Amperes
5,000
www.baldormotion.com
General Information 1-3