Table 4-2 Pinout Of Connector X5 - Siemens SIMATIC FM 453 Manual

Servo drive / step drive positioning module
Hide thumbs Also See for SIMATIC FM 453:
Table of Contents

Advertisement

Wiring the FM 453
Connector Pinout
Connector identifier:
Connector type:
Table 4-2
Pinout of Connector X5
Pin
Name
1
not assigned
2
BS1
3
SW2
4
BS3
5
PULSE1
6
DIR1
7
PULSE2_N
8
DIR2_N
9
PULSE3
10
DIR3
11
PWM1/BOOST1
12
PWM1_N/
BOOST1_N
13
READY1_1_N
14
not assigned
15
RF1_1
16
RF2_1
17
RF3_1
Signal Names
For step drives:
PULSE[1...3], PULSE[1...3]_N
DIR[1...3], DIR[1...3]_N
ENABLE[1...3], ENABLE[1...3]_N
PWM[1...3]/BOOST[1...3],
PWM[1...3]_N/BOOST[1...3]_N
READY1[1...3]_N
M
For analog drives:
SW[1...3]
BS[1...3]
RF[1.1...3.1], RF[1.2...3.2]
Signal Type
O
I
VO
K
4-6
X5 ANALOG OUT / STEP. CONTR. / (1...3)
50-pin sub-D plug connector
Type
Pin
Name
18
ENABLE1
VO
19
ENABLE1_N
VO
20
ENABLE2
VO
21
ENABLE2_N
O
22
M
O
23
M
O
24
M
O
25
M
O
26
ENABLE3
O
27
ENABLE3_N
O
28
PWM2/BOOST2
O
29
PWM2_N/
BOOST2_N
I
30
READY1_2_N
31
not assigned
K
32
not assigned
K
33
not assigned
K
Signal output
Signal input
Voltage outlet
Switching contact
Type
Pin
Name
O
34
not assigned
O
35
SW1
O
36
BS2
O
37
SW3
38
PULSE1_N
39
DIR1_N
40
PULSE2
41
DIR2
I
42
PULSE3_N
I
43
DIR3_N
O
44
PWM3/BOOST3
O
45
PWM3_N/
BOOST3_N
I
46
READY1_3_N
47
not assigned
48
RF1_2
49
RF2_2
50
RF3_2
Clock pulse, true and negated
Direction signal, true and negated
Enable signal, true and negated
Current generation, true
Current generation, negated
Ready message 1
Signal ground
Setpoint
Reference potential for setpoint (analog
ground)
Contact for CL controller enable
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Type
VO
VO
VO
O
O
O
O
O
O
O
O
I
K
K
K

Advertisement