Siemens SIMATIC FM 453 Manual page 348

Servo drive / step drive positioning module
Hide thumbs Also See for SIMATIC FM 453:
Table of Contents

Advertisement

Troubleshooting
Table 11-8
General Data Errors, Machine Data Errors, Traversing Program Errors, continued
Cl.
No.
Machine data errors
5 (05) 100 (64)
Maximum velocity for drive too high
Cause
Effect
Elimina-
tion
5 (05) 101 (65)
Impermissible increment evaluation factor for step drive
Cause
Effect
Elimina-
tion
5 (05) 102 (66)
Limitation, software limit for linear axis
Cause
Effect
Elimina-
tion
Cl. = Detail event class, No. = Detail event number, CBS = Checkback signals, DB = Data block
Note: Value (xx) = Hexadecimal notation of the error number.
11-32
Error Message,
Error Analysis and Elimination
Error response: "Warning" see Table 11-2
Based on the MD11, MD12 and MD52 machine data for the maxi-
mum velocity MD23, a frequency would be generated that is
greater than MD56.
DB does not become effective and is stored non-retentively.
Correct and retransmit.
Impermissible relationship in the assignments for distance per en-
coder revolution (MD11, 12) and steps per motor revolution
(MD52).
DB does not become effective and is stored non-retentively.
Correct and retransmit.
For encoder resolutions/step resolutions < 1 MSR, the permissible
traversing range in the ratio of MSR to increments is limited (e.g.
for 0.5 µm per encoder pulse to 0.5 10
DB does not become effective and is stored non-retentively.
Correct and retransmit.
9
MSR).
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Message/
Display
CBS
or
DB
CBS
or
DB
CBS
or
DB

Advertisement

Table of Contents
loading

Table of Contents