Programming the FM 453
6.2
FC MODE_WR (FC 2) – Control Operating Modes and Process Write
Jobs
Task
You can use FC MODE_WR to:
You must call FC MODE_WR once per channel in the OB 1 cycle.
The FC performs the following actions:
1. Reads the checkback signals. The values read by the FC are stored in the
2. Transfers the control signals from the user DB (structure CON-
3. Executes the write job from the user DB (JOB_WR), transfers the
4. Generates the status bits JOB_WR.MODE_BUSY (operating mode busy,
Call Options
Description of
The following table describes the parameters of this FC.
Parameters
DB_NO
RET_VAL INT
Parameter types: I = input parameter, Q = output parameter
6-6
Control modes
Process write jobs
user DB in the structure CHECKBACK_SIGNALS.
TROL_SIGNALS). Depending on the mode selected (CHECK-
BACK_SIGNALS.MODE) control signals CONTROL_SIG-
NALS.START, CONTROL_SIGNALS.DIR_P and
CONTROL_SIGNALS.DIR_M are cleared when a start is detected (edge
generation of signals for FM).
associated data from the user DB, and displays the write job status.
i.e. started) and JOB_WR.POS_REACHED (position reached).
Call in LAD Notation
(ladder diagram)
FC MODE_WR
EN
DB_NO
RET_VAL
Name
Data
P
Type
Type
WORD
I
Q
Call in STL Notation
(statement list)
CALL MODE_WR(
ENO
DB_NO
RET_VAL
Meaning
Data block number
Return code of SFC 58 "WR_REC"