Table 5-8 Db Structure - Traversing Programs - Siemens SIMATIC FM 453 Manual

Servo drive / step drive positioning module
Hide thumbs Also See for SIMATIC FM 453:
Table of Contents

Advertisement

Defining Parameters of the FM 453
5.3.4
Traversing Programs
DB Structure
Table 5-8 gives you a general view of the structure of the "traversing pro-
grams" data block (DB-NC).
DB No.: 1001...1199 for channel 1
DB No.: 1301...1499 for channel 2
DB No.: 1601...1799 for channel 3
Table 5-8
DB Structure – Traversing Programs
Address
Variable Type
0
WORD
2
WORD
4
DWORD
8
WORD
10
WORD
1
12
2 STRING
NC
16
DWORD
453
20
4 CHAR
0
24
DWORD
1 – 3
28
WORD
30
WORD
32
18 STRING
ASCII char.
52
STRUCT
NC block
72
STRUCT
NC block
92
STRUCT
NC block
5-24
Value
Significance of the Variables
DB header (36 bytes)
Rack slot
DB No. (
1000)
Reserved
Error No. (from FM)
Channel number
DB identifier/type
Module identifier
Version number/block number
Measurement-system grid per MD7
Reserved
Reserved
NC program name
NC block new (modification range)
1st traversing block
2nd to 100th traversing block
Module address
As in DB header
With MMI services
2 ASCII characters
FM 453
(DB structure)
Unit of measurement
max. 18 characters
see Sections 9.3.11, 10.1
FM 453 Servo Drive / Step Drive Positioning Module
C79000-G7076-C453-01
Comment

Advertisement

Table of Contents
loading

Table of Contents