Siemens SIMATIC FM 353 Manual page 320

Stepper drive positioning module
Hide thumbs Also See for SIMATIC FM 353:
Table of Contents

Advertisement

Troubleshooting
Table 11-7
Travel errors, continued
Cl.
No.
Travel errors
3 (03)
30 (1E)
Digital input not parameterized
Cause
Effect
Elimination
3 (03)
35 (23)
Tool offset value not in place
Cause
Effect
Elimination
3 (03)
36 (24)
Set actual value on the fly, incorrect value
Cause
Effect
Elimination
3 (03)
37 (25)
MDI block on the fly, incorrect syntax
Cause
Effect
Elimination
3 (03)
38 (26)
MDI block on the fly, incorrect velocity
Cause
Effect
Elimination
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note: Value (xx) = Hexadecimal notation of the error number
11-18
Error message,
error analysis and remedy
Error response: "Feed STOP" see Table 11-2
For the following functions, no necessary digital input is para-
meterized:
S
Set travel with actual value on the fly (G88, G89)
S
External block change (G50)
S
Measurement
S
Rotation monitoring
Functions are not started.
Parameterization of the digital inputs by way of MD34 or
MD37
No tool offset values are available on the FM 353 or tool off-
sets are accessed and modified when an override is active.
Parameterize and read in tool offset values
Value is no longer within the range"10
Input a correct value
Incorrect M or G commands or incorrect block structure
Input a correct MDI block
Velocity not within the range between > 0 and max. allowable
traverse velocity (500 000 000 MSR/min)
Input a correct MDI block
9
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Mes-
sage/
Display
CBS
CBS
CBS
CBS
CBS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents