Siemens SIMATIC FM 353 Manual page 209

Stepper drive positioning module
Hide thumbs Also See for SIMATIC FM 353:
Table of Contents

Advertisement

Table 9-2
Checkback signals, continued
Symbol
Significance
English
Ger-
Significance
man
POS_RCD
PEH
Position
reached,
Stop ("PEH")
ACT_POS
ACT_
Actual posi-
POS
tion
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
S
When the preset target position is reached correctly, (PEH) is
actuated, and remains in effect until the next axis movement.
S
(PEH) is actuated only in the following modes and cases:
− Reference-point approach: If the reference point has
been reached in full (including reference-point shift).
− MDI, Incremental relative: If the preset position has been
reached.
− Automatic: If a traversing block has been positioned in full
and the axis remains motionless until the next traversing
movement.
S
It is not set if no synchronization is available yet.
The firmware version V3.8 of the FM 353 positioning module in
conjunction with the blocks of the "FM353_354" block library pro-
vides direct access to the actual value. This is stored in the
checkback signals during the module cycle (2 ms) and read by
the POS_CTRL block. In addition, as previously, the actual value
is included as a DINT variable in the basic operating data read
request.
Description of Functions
Function
Function
9-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents