Siemens SIMATIC FM 353 Manual page 229

Stepper drive positioning module
Hide thumbs Also See for SIMATIC FM 353:
Table of Contents

Advertisement

Handling by the user
The table below gives you an overview of how to handle this mode.
Triggering of movement
Start
"MDI block on-the-fly" transmitted
to the FM 353
Note
Please see also Section 9.1.3!
Control actions
Prerequisites:
S The FM 353 has been initialized.
S The mode has been selected and acknowledged.
S Drive Enable [AF] is = 1 (control signal in user DB, DBX15.7)
S Stop [STP] is = 0 (control signal in user DB, DBX15.1)
S Servo Enable (RF) is = 1 (user DB, DBX34.0)
S Axis is synchronized.
Table 9-7
Control actions for "MDI" mode (examples)
Signal name
Control action 1, define position
Transfer MDI block
(DBX38.3)
Control signal:
Start [ST]
Checkback signals:
e.g. Travel plus [FR+]
Start enable [SFG]
Processing in progr. [BL]
e.g. Travel plus [FR+]
Processing in progr. [BL]
Position reached, stop
[PEH]
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
as defined by "MDI block"
(user DB, DBX38.3)
as defined by "MDI block on-the-fly"
(user DB, DBX38.4)
Level
When the MDI block has been transferred, [ST] can be
initiated.
The axis cancels the [SFG] and outputs messages
[BL] and [FR+]
When the defined position has been reached, the axis
enables [PEH]; [SFG] and checkback signals [FR+]
and [BL] are reset.
Description of Functions
Type of movement
Explanation
9-29

Hide quick links:

Advertisement

Table of Contents
loading