Replacing The Developer - Canon CLC5100 Series Manual

Table of Contents

Advertisement

Reference
The height (position) of the charging wire may be
adjusted by turning the screw found behind the corona
assembly. (The height of the charging wire for the
primary charging assembly, however, cannot be
adjusted.) A full turn of the screw changes the position
of the charging wire by about 0. 7 mm.
Points to Note When Handling the Primary Grid Plate
and the Primary Charging Wire
Do not clean the primary grid plate or the rimary
charging wire. If image faults (uneven density)
occurs, replace the part.
2.5.4
Replacing
Developer
CLC5100 / CLC4000
1) Insert the door switch actuator into the door switch
assembly.
2) Turn on the power, and insert and turn the control
key.
3) Start service mode, and select 'FUNC >IN STALL'.
4) Select the 2nd screen, and set 'LSNSKIL' to '1'.
5) Select '0' by executing 'ADJSUT > PASCAL >
PASCAL'.
6) Wait until warm up ends.
7) Lift the hopper assembly [1] to the topmost
position. (At this time, the locking mechanism [2]
will turn on automatically. Make a visual check of
the hopper assembly to make sure that the hopper
assembly is locked.)
8) Install the hopper retaining fixings [3] (left, right).
9) Release the hopper assembly, and move the
assembly down to where the retaining fixings are
located.
the
0002-5791
F-2-41
10) Install the laser shutter opening tool.
[1]
[2]
F-2-42
[1]Laser shutter
[2]Shutter pushing member
[3]Laser shutter pushing member
[4]Groove
11) Raise the hopper assembly as far as it moves, and
operate the locking mechanism by hand; then,
remove the hopper metal fixings (left, right).
12) Slide out the transfer assembly.
13) Place the collecting container [1] as shown.
Chapter 2
[1]
[4]
[1]
[3]
[1]
2-21