0001
Transfer belt edge sensor 1 (PS17; fault)
Transfer belt edge sensor 2 (PS18; fault)
0002
Transfer belt edge sensor 1 (PS19; fault)
Transfer belt edge sensor 2 (PS20; fault)
0003
Transfer belt swing motor (M13; fault)
DC controller PCB (fault)
0004
E076
The transfer belt cleaner belt motor is
faulty.
0001
The connection between the motor and the
DC controller PCB is faulty.
The DC controller PCB is faulty.
The transfer belt cleaner web has been taken
up.
0002
The web length sensor is faulty.
The DC controller PCB is faulty.
E077
The transfer belt waste toner motor is
faulty.
0001
The connection between the moor and the
DC controller PCB is faulty.
The DC controller PCB is faulty.
high order 2 digits
E100
xx=00:common error xx=01:Y xx=02:M xx=03:C xx=04:BK
xx01
Laser unit (faulty)
Laser driver PCB (faulty)
Image processor PCB (faulty)
xx02
Laser scanner drive system (overload)
E110
Laser scanner motor (M4; faulty)
DC controller PCB (faulty)
high order 2 digits
E194
xx=00:common error xx=01:Y xx=02:M xx=03:C xx=04:BK
3-14
Cause
The transfer belt edge sensor 1 (PS17) does not turn off
200 sec after it has detected the belt.
The transfer belt edge sensor 2 (PS18) does not turn off
200 sec after it has detected the belt.
The transfer belt edge sensor 3 (PS19) detected the
transfer belt.
The transfer belt edge sensor 4 (PS20) detected the
transfer belt.
The error detection circuit on the DC controller PCB has
detected overcurrent in the transfer belt waste toner
motor drive circuit.
An excess load is imposed on the transfer belt cleaning
web motor (M12) because of the shortage of the web,
causing the cleaning web rotation sensor (PS10) to detect
faulty rotation.
The error detection circuit on the DC controller PCB has
detected overcurrent in the transfer belt waste toner
motor drive circuit.
At the start of potential control, the BD signal is not
detected for 1 sec or more.
The operation ON current used to obtain optimum
intensity is larger than a specific value.
The rotation speed of the motor has deviated from a
specific value for 0.1 sec or more.
Description