Code
Upper delivery roller home position sensor
0002
(PI6)
E562
0001
Lower offset motor (M5)
Lower delivery roller home position sensor
0002
(PI7)
E577
0001
Upper paddle motor (M6)
0002
Upper paddle home position sensor (PI8)
E579
0001
Lower paddle motor (M7)
0002
Lower paddle home position sensor (PI9)
E599
DC output (from sorter controller; faulty)
IP MAIN PCB (faulty)
E620
IP ED PCB (faulty)
E634
Film projector lamp (faulty)
DC controller PCB (faulty)
E700
Reader unit controller PCB (faulty)
Power supply PCB (faulty)
IP MAIN PCB (faulty)
E718
Film projector controller PCB (faulty)
Power switch
E800
DC controller PCB
DC harness
E804
Power supply unit (DCP1) cooling fan FM
0001
17/18 (error)
E805
3-20
Cause
When the upper delivery roller is performing shift
operation and does not move from home position after 1
second has elapsed.
When the lower delivery roller is performing shift
operation and does not return to home position after 1
second has elapsed.
When the lower delivery roller is performing shift
operation and does not move from home position after 1
second has elapsed.
When the upper paddle is operating and does not return
to home position after 1.2 seconds has elapsed.
When the upper paddle is operating and does not move
from home position after 1.2 seconds has elapsed.
When the lower paddle is operating and does not return
to home position after 1.2 seconds has elapsed.
When the lower paddle is operating and does not move
from home position after 1.2 seconds has elapsed.
An error has occurred in the DC output (24 VL, 24 VP)
from the sorter con troller PCB.
The communication between the IP ED PCB and the IP
MAIN PCB is interrupted for 5 sec or more.
See the Service Manual for the film projector.
The communication between the DC controller PCB and
the reader unit controller PCB is disrupted for 5 sec or
more.
The communication between the IP MAIN PCB and the
film projector is interrupted for 5 sec or more.
An interruption in the auto shut off signal is detected for
1 sec or more.
The rotation of the cooling fan for the power supply unit
(DCP1) has stopped.