SMC Networks PSE200 Operation Manual page 8

Multi channel pressure sensor controller
Hide thumbs Also See for PSE200:
Table of Contents

Advertisement

•If using the product to detect very small pressure rates, warm up the product for 20 to 30 minutes first.
There will be a drift on the display of approximate 1% immediately after the power supply is turned on.
•Perform settings suitable for the operating conditions.
Incorrect setting can cause operation failure.
For details of each setting, refer to page 18 to 27 of this manual.
•Do not touch the LCD during operation.
The display can vary due to static electricity.
∗Maintenance
•Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of
air before performing maintenance.
There is a risk of unexpected malfunction.
•Perform regular maintenance and inspections.
There is a risk of unexpected malfunction.
•Perform drainage regularly.
If condensate enters the secondary side, it can cause operating failure of pneumatic equipment.
•Do not use solvents such as benzene, thinner etc. to clean the Controller.
They could damage the surface of the body and erase the markings on the body.
Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully
squeezed, then wipe up the stains again with a dry cloth.