SMC Networks PSE575 Operation Manual

Pressure sensor for general fluids
Hide thumbs Also See for PSE575:

Advertisement

Quick Links

No.PS※※-OMT0006-B
PRODUCT NAME
Pressure Sensor for General Fluids
MODEL / Series / Product Number
PSE575/576/577

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSE575 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks PSE575

  • Page 1 No.PS※※-OMT0006-B PRODUCT NAME Pressure Sensor for General Fluids MODEL / Series / Product Number PSE575/576/577...
  • Page 2: Table Of Contents

    Table of Contents Safety Instructions Model Identification and How to Order Names of Parts of Product and Handling Precautions Mounting and Installation Wiring Troubleshooting Specification Specifications Dimensions No.PS※※-OMT0006-B...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations *1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.
  • Page 4 Safety Instructions Caution 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5 Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
  • Page 6 Caution ■After maintenance is complete, perform appropriate functional inspections and leak tests. Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurs from parts other than the piping, the product might be faulty. Disconnect the power supply and stop the fluid supply.
  • Page 7 ●Product handling Installation Follow the specified tightening torque. Excessive tightening torque can break the Pressure Sensor. Insufficient tightening torque can displace the Pressure Sensor from the original position or loosen the mounting screws. Refer to the following table for the appropriate torque values. Nominal size screws Appropriate tightening torque (Nm) R1/4...
  • Page 8 Environment Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam. Otherwise failure or malfunction can result. Do not use in a place where the product could be splashed by oil or chemicals. If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires).
  • Page 9: Model Identification And How To Order

    Model Indication and How to Order ○Option Description Part No. Remarks Lead wire and M12 connector (3 m) Straight ZS-37-A 1 pc. Lead wire and M12 connector (3 m) Right angle ZS-37-B 1 pc. Adapter with throttle Rc1/4 ZS-31-X175 1 pc. No.PS※※-OMT0006-B...
  • Page 10: Names Of Parts Of Product And Handling Precautions

    Names of Parts of Product and Handling Precautions ○Names of parts of product •Only fluids which are non-corrosive to C3604 + electroless nickel plated, AI203 (aluminum oxide) and FKM should be used. ○Handling precautions •When piping, apply a spanner to the piping section of the sensor. Nominal size screws Appropriate tightening torque (Nm) R1/4...
  • Page 11: Mounting And Installation

    Mounting and Installation ■Wiring ○Connector pin numbers When the lead wire and connector (ZS-37-A or ZS-37-B) designated for the PSE570 is used, the wire colours will apply as shown in the diagram. Connector pin numbers (on the lead wire) •ZS-37-A •ZS-37-B Pin No.
  • Page 12 ○How to connect the body and the lead wire and connector Align the lead wire connector with the connector key groove, and insert vertically. Connection is complete when the knurled part is fully tightened. Check that the connection is not loose. ○Internal circuit and wiring example Output specification PSE57□-02...
  • Page 13: Troubleshooting

    Troubleshooting ○Cross-reference for troubleshooting Problem Possible cause Investigation method Countermeasure Check if the analogue output line is Incorrect wiring Correct the wiring. connected with a load. Non-compliance (1) Check if the proper load is connected. with the load (2) Check if input impedance of input Connect a proper load.
  • Page 14: Specification

    Specification ■Specifications Model PSE575 PSE576 PSE577 Rated pressure range 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Pressure spec. Withstand pressure 5 MPa 12.5 MPa 30 MPa Temperature characteristics ±5%F.S. (at 25 PSE57□-02 PSE57□-02-28 Model Fluid...
  • Page 15 ○Analogue output Model Rated pressure range PSE575 0 to 2 MPa 2 MPa PSE576 0 to 5 MPa 5 MPa PSE577 0 to 10 MPa 10 MPa -14- No.PS※※-OMT0006-B...
  • Page 16: Dimensions

    ■Dimensions Lead wire and connector ZS-37-A ZS-37-B Adapter with throttle ZS-31-X175 -15- No.PS※※-OMT0006-B...
  • Page 17 Revision history A: Contents revised in several places. B: Contents revised in several places. [July 2018] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. ©...

This manual is also suitable for:

Pse577Pse576

Table of Contents