PSE##-TFI52GB
Installation & Maintenance Manual
Compact Pressure Sensor
Series PSE530
EMC Directive 89/336/EEC
EN61000-6-2:2001 Electromagnetic Compatibility (EMC). Generic
standards - lmmunity for industrial environments.
EN55011+A1:1998 Limits and methods of measurement of radio
disturbance characteristics of industrial, scientific
and medical radio-frequency equipment and light
industrial environments.
Safety Instructions
The Pressure Sensor and this manual contain essential information for
the protection of users and others from possible injury and property
damage and to ensure correct handling.
Please check that you fully understand the definition of the following
messages (signs) before going on to read the text, and always follow the
instructions.
IMPORTANT MESSAGES
Read this manual and follow its instructions. Signal words such as
WARNING and NOTE will be followed by important safety
information that must be carefully reviewed.
Indicates a potentially hazardous situation that
could result in death or serious injury if you do
not follow instructions.
Gives you helpful information.
Do not disassemble, modify ( including change of printed
circuit board ) or repair.
An injury or failure can result.
Do not operate outside of the specification range.
Fire, malfunction or sensor damage can result.
Please use after confirming the specification.
Do not operate in atmosphere of an inflammable, explosive
or corrosive gas.
Fire, an explosion and corrosion can result.
This pressure sensor is not an explosion proof type.
NOTE
Follow the instructions given below when handling the
pressure sensor. Otherwise, the sensor may be damaged or
may fail, thereby resulting in malfunction.
•Do not drop, bring into collision with other objects or apply excessive
shock to the unit ( 980m/s
2
or more).
•Do not pull the lead wire with force or lift the main unit by holding the
lead wire. ( Pulling strength less than 23N)
•Do not insert wire or other articles into the pressure port.
•Connect wires and cables correctly.
•Do not perform wiring while power is on.
•Do not wire with power cable or high-voltage cable in the same wire
route.
•Connect Terminal FG to ground when using a switching regulator
obtained on the commercial market.
•Install the air tube correctly in a safe area away from water and dust.
Model Indication Method
PSE53 0
M5
Pressure sensing range
High pressure[0 to 1MPa]
0
1
Vacuum [0 to -101kPa]
2
Low pressure [0 to 101kPa]
3
Compound pressure [-101 to 101kPa]
Pipe Specification
M5
M5
0.8
R06
6 reducer
R07
1/4inch reducer
Option
Nil
Without cable
Sensor cable (3m), ZS-26-F
L
Connector for sensor controller (1pc)
+
Sensor cable (3m), ZS-26-J
C2L
Note) At the factory, the connector (ZS-28-C) is not connected
to the cable, but packed together with it for shipment.
Outline with Dimensions
in mm
(
)
PSE53 -M5
M5
0.8
3.4
29.4
Pressure port
27.2
3
4
5 5.5
PSE53 - R06
R07
45.5
Pressure port
3.4
43.3
Model No.
Applicable port size(D)
PSE53 -R06
6mm
PSE53 -R07
1/4inch
With sensor cable fitted
9.8
Specification
Model No.
PSE530-
PSE531-
Rated Pressure Range
0 to 1MPa
0 to -101kPa
Withstand Pressure
1.5MPa
Fluid
Air, Non-corrosive gases, Non-flammable gases
Power Supply
12 to 24VDC, ripple(p-p)10% or less (Protection against inverse connection)
Current Consumption
15mA or less
Analog
Voltage
Voltage: 1 to 5V
2%F.S. or less (Rated pressure range)
Output
Output
Linearity :
1%F.S. or less Output impedance : Approx.1k
Repeatability
1%F.S. or less
Power Supply Effect
1%F.S. or less based on analog output at 18V in the range of 12 to 24VDC
Temperature Characteristic
2%F.S. or less (25
Enclosure
IP40 (IEC 60529)
Operation : 0 to 50 ,Storage :-10 to 70
Ambient Temperature
1000VAC, 50/60Hz, 1minute (Between wires and case)
Withstand Voltage
Insulation Resistance
5M
or more 500VDC (Between wires and case)
10 to 500Hz 1.5mm or 98m/s
Vibration Proof
of X, Y and Z
Impact Proof
980m/s
2
3times each in directions of X ,Y and Z respectively
Standard
CE MARKING
Cable
Halogen free heavy insulation cable,
Material Specification
Model No.
M5
Port Size
M5
0.8
Pressure sensor : Silicon O-ring : NBR
Material
Body : SUS303
With cable(3m)
41g
Weight
Excluding cable
7g
Analog output
1 to 5VDC
5
1
12
A
B
Model No.
PSE530-
PSE531-
Rated pressure
0 to 1MPa
0 to -101kPa
range
0kPa
0kPa
A
B
1MPa
-101kPa
Installation
Observe the specified tightening torque when connecting pipes.
PSE532-
PSE533-
Refer to the following table for the appropriate torque values.
0 to 101kPa
-101 to 101kPa
500kPa
Nominal size of Thread
M5
When connecting pipeline to the
sensor, apply a spanner vertically
to the piping section of the sensor.
Install the air piping correctly in a
safe area away from water and
dust.
reference)
(No condensation, No freezing)
2
acceleration, 2 hours each direction
Hold the sensor and insert it into the
one-touch fitting carefully and securely
all the way to the bottom.
2.7, 0.15mm
2
, 3wire, 3m
R06
R07
6 Reducer
1/4inch Reducer
Body : PBT
38g
3.8g
Pressure or Vacuum
PSE532-
PSE533-
0 to 101kPa
-101 to 101kPa
0kPa
-101kPa
101kPa
101kPa
Tightening torque N • m
1/6 rotations after tightening by hand
Need help?
Do you have a question about the PSE530 Series and is the answer not in the manual?
Questions and answers