Installation location

Devices can be mounted in a standard 19-inch equipment rack or on a flat surface.
The site should meet the following requirements:
Maintain the operating environment as specified in the section
Operate at temperatures within 0° to 45° C (32° to 113° F) and humidity levels within 5% to 95%, non-condensing.
Allow a minimum of 7.62 cm (3 in.) of space between the front and the back of the device and walls or other obstructions for
proper airflow.
Allow at least 7.62 cm (3 in.) of space at the front and back of the device for the twisted-pair, fiber-optic, and power cabling.
The site should be accessible for installing, cabling, and maintaining the devices.
Allow the status LEDs to be clearly visible.
Allow for twisted-pair cable to be routed away from power lines, fluorescent lighting fixtures, and other sources of electrical
interference, such as radios and transmitters.
For a unit with AC power, allow for the unit to be connected to a separate grounded power outlet that provides 100 to 240
VAC, 50 to 60 Hz, is within 2 m (6.6 feet) of each device, and is powered from an independent circuit breaker. As with any
equipment, a filter or surge suppressor is recommended.
For a unit with DC power, allow for the unit to be connected to a separate grounded power outlet that provides 40 to 72 VDC, is
within 2 m (6.6 feet) of each device, and is powered from an independent circuit breaker. As with any equipment, a filter or surge
suppressor is recommended.
Some combinations of intake and exhaust airflow may not be compatible with your environment. Consult your fan and power
supply module field-replaceable unit (FRU) kit to determine the correct configuration.
For a four-post rail mount configuration, order the appropriate mounting kit and refer to the kit documentation.

Installing the device

You can install the device on a desktop or in an equipment rack.
DANGER
Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over.

Desktop installation

Use the following steps to install the ICX 6610 on a desktop or other flat surface.
Brocade ICX 6610 Stackable Switch Hardware Installation Guide
53-1003620-03
Connector type
Core diameter
(microns)
9 µ
LC
9 µ
LC
QSFP+
n/a
50 μ
MTP (MPO) 1×8 or
1×12 ribbon
connector
Environmental requirements
Modal bandwidth
Range
(MHz*km)
n/a
15 km
n/a
40 km
n/a
1 and 5 m
2000 MHz*km
100 m
4700 MHz*km
150 m
on page 86.

Installing the device

29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents