Managing The Icx 6610 Hardware; Managing Temperature Settings; Using The Temperature Sensor; Displaying The Temperature - Brocade Communications Systems ICX 6610 Installation Manual

Stackable switch
Hide thumbs Also See for ICX 6610:
Table of Contents

Advertisement

Managing the ICX 6610 Hardware

Managing temperature settings...................................................................................................................................................................79
Removing MAC address entries..................................................................................................................................................................82
Displaying ICX 6610 CPU usage.............................................................................................................................................................. 82
Hardware maintenance schedule................................................................................................................................................................ 82
Removing a copper or fiber-optic module..............................................................................................................................................83
Cabling a fiber-optic module........................................................................................................................................................................ 84
Cleaning the fiber-optic connectors...........................................................................................................................................................84
DANGER
The procedures in this manual are for qualified service personnel.

Managing temperature settings

This section describes how to display temperature settings on the device and how to change the temperature warning and shutdown
levels.

Using the temperature sensor

The device contains temperature sensors that the software reads based on a configurable device poll time. To protect the device from
overheating, the following temperature threshold levels exist:
The warning level is the temperature at which the device generates a Syslog message and SNMP trap. It is configurable.
The shutdown level is the temperature at which the device reboots. It is set by the device and is not configurable.
The fan speed settings are set by the device, and are not configurable.

Displaying the temperature

To display the temperature of a device, enter the show chassis command at any level of the CLI.
NOTE
The displayed temperature reflects the temperature of the board inside the
device.
device#show chassis
The stack unit 1 chassis info:
Power supply 1 not present
Power supply 2 (NA - AC - Regular) present, status ok
Power supply 2 Fan Air Flow Direction:
Fan 1 ok, speed (auto): [[1]]<->2
Fan 2 not present
Fan controlled temperature: 53.5 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->80
Speed 2:
Fan 1 Air Flow Direction:
MAC 1 Temperature Readings:
Current temperature : 32.5 deg-C
MAC 2 Temperature Readings:
Current temperature : 46.5 deg-C
CPU Temperature Readings:
Current temperature : 39.5 deg-C
Brocade ICX 6610 Stackable Switch Hardware Installation Guide
53-1003620-03
Front to Back
deg-C
75<-----> 85 deg-C (shutdown)