Installing the device
FIGURE 20 Attaching the adhesive feet
1.
Attach the four adhesive feet to the bottom of the first switch. If installing multiple switches, attach the adhesive feet to each one.
Place each device squarely on top of the one below.
2.
Set the device on a flat desktop, table, or shelf near an AC or a DC power source, whichever is appropriate for your installation.
Make sure that adequate ventilation is provided for the system. A 3 inch clearance is recommended on each side.
3.
If installing a single switch only, refer to the section

Rack mount installation

NOTE
You will need a Phillips screwdriver for installation.
Before mounting the switch in a rack, pay particular attention to the following factors:
Temperature: Because the temperature within a rack assembly may be higher than the ambient room temperature, check that
the rack-environment temperature is within the specified operating temperature range.
Mechanical loading: Do not place any equipment on top of a rack-mounted unit.
Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.
Grounding: Rack-mounted equipment should be properly grounded. Be sure to check supply connections in addition to direct
connections to the mains.
30
Powering on the system
on page 55.
Brocade ICX 6610 Stackable Switch Hardware Installation Guide
53-1003620-03