In the second test example, the TDR test results for the same port show details for an active port.
device>show cable-diagnostics tdr 1/1/1
Port
Speed Local pair Pair Length Remote pair Pair status
--------- ----- ---------- ----------- ----------- -----------
01
1000M
Syntax: show cable-diagnostics tdr stackid/slot/port
In the output shown, "Local pair" indicates the assignment of wire pairs from left to right, where Pair A is the left-most pair. The following
table shows the "Local pair" mapping to the T568A pin/pair and color assignment from the TIA/EIA-568-B standard.
TABLE 18 Local pair definition
Local pair
Pair A
Pair B
Pair C
Pair D
The following figure illustrates the T568A pin/pair assignment.
FIGURE 53 T568A pin/pair assignment
The following table describes the fields shown in the show cable-diagnostics port command output.
Brocade ICX 6610 Stackable Switch Hardware Installation Guide
53-1003620-03
Pair A
<50M
Pair B
<50M
Pair C
<50M
Pair D
<50M
Pair B
Terminated
Pair A
Terminated
Pair D
Terminated
Pair C
Terminated
T568A pair and color assignment
Pair 3 (green)
Pair 2 (orange)
Pair 1 (blue)
Pair 4 (brown)
Troubleshooting network connections