Auto-Axcess DI/E Digital

6.2.1 MILLER-PROG-SEL Macro

6
Miller Auto-Axcess E Digital
6.2 MACRO Job Settings
Use this macro routine to specify the weld program at the start of a weld or
change the weld program mid-weld. It also allows adjustment of the arc
characteristics for the specified program. These characteristics can be
changed either at the beginning or mid-weld if desired
• Welder Number: Allows specification of the desired welder.
Allowable values are 1 to 4.
• Program Number: Allows specification of program number. The
number entered specifies which of the eight programs in the welder
to execute. Allowable values are 1 to 8 (a value of 0 will allow weld
settings to be specified from the front-panel of the welder)
• Inductance/Ctrl: Depending on the welding process selected this
control has different meanings and acceptable ranges:
MIG: In MIG processes this controls the welder's "Inductance"
setting where the range is 0-99. The default inductance is a value of
30.
Synergic (pulse): In synergic mode this controls the welder's
"Arc Control" setting. The range is 1-50 with a default value of 25.
• Slope:
MIG: In MIG processes this contols the welder's "Slope" setting
where the range is 1-99. The default slope setting is a value of 50.
Synergic (pulse): In synergic mode this control has no impact
Fig. 6-3: Miller-PROG-SEL Screent
6-4
166465-1CD
166465-1CD
46/56

Hide quick links: