Calibration Verification - YASKAWA MOTOMAN DX100 Instruction Manual

Programming pendant cheat sheet
Hide thumbs Also See for MOTOMAN DX100:
Table of Contents

Advertisement

166465-1CD
Auto-Axcess DI/E Digital

5.1.4 Calibration Verification

Table 5-2: Calibration Test Examples
Mig Mode
Required Setting
100 ipm
350 ipm
700 ipm
Pulse/ACC-PULSE
Required Setting
100 ipm
350 ipm
700 ipm
5
Operation
5.1 Set-Up Overview
The Digital Interface uses direct settings, no special
NOTE
procedures like AutoCal are required.
To verify power supply calibration:
1. Insert an ARCSET command into a job.
2. Select the ARCSET command from the instruction side of the job line.
3. Press [SELECT]. The ARCSET command appears on the input buffer
line.
4. Press [SELECT]. The Detail Edit screen appears.
5. Cursor to CURRENT and press [SELECT] or [AC=]. Referring to the
calibration test examples, enter sample data using the number keypad
(examples: AC=100; AC=300). Press [ENTER].
6. Cursor to VOLTAGE and press [SELECT] or [AV =]. Referring to the
calibration test examples, enter sample data using the number keypad
(examples: AV=15; AV=25). Press [ENTER] twice.
7. Execute the command by holding down the INT LOCK key and
pressing FWD. Each time a value is executed, look at the display on
the power supply and verify the requested value matches the set
value. To change the display on the power supply, press the WFS/A
button on the Miller Auto-Axcess DI until the Wire Feed Speed LED
lights.
AC = WFS
100
350
700
AC = WFS
100
350
700
To determine the value for Arc Length in Pulse, Accupulse
NOTE
or RMD mode, the power supply doubles the requested
voltage value and converts it to a percentage value.
5-3
Required Setting
AV = Voltage
20 volts
20.0
25 volts
25.0
35 volts
35.0
Required Setting
AV = Arc Length
40%
20.0
50%
25.0
70%
35.0
166465-1CD
39/56