Auto-Axcess DI/E Digital
Fig. 3-8: View All Welders

3.5.7 To Modify or Add a Welder

3
Equipment Description
3.5 Miller-Motoman Pendant Interface (HMI) Software
9. Gas: Red=Gas solenoid off. Green=Gas solenoid on.
10. Contactor: Red=welder in standby. Green=Gun Switch is on.
11. View All Welders: Displays the Viewing Weld Data for All Welders
screen () on top of the Live Weld Data screen. When returning from
the Viewing Weld Data for All Welders screen to the Live Weld Data
screen, the Restart Data Read button must be pressed to display live
weld data again.
12. Restart Data Read: This button restarts the live weld data stream from
the welder to the pendant. It must be pushed whenever the screen is
left and returned to via the View All Welders or Back to Pendant
buttons. Pushing it tells the welder to begin sending actual weld data
again.
Only possible with the DeviceNet interface.
If a welder is to be added to a DeviceNet connected system or the starting
input address has changed due to the addition of other options use the
screen shown in Fig. 3-9. If an additional welder is added, the starting
address will not change, but ladder modifications may be needed. Some
options, such as an Expanded I/O pc board, will require address changes
as well as updating the DX100 ladder for the new address locations.
Changing information on this screen requires the user to be in Manager
mode.
• Changing the starting address location will make the
system inoperable without also updating the User Section
of the DX100 ladder to reflect the change.
NOTE
• Adding a welder without also updating the DX100 System
and User sections of the ladder will make the system
inoperable.