Operation; Set-Up Overview; Welder Condition File - YASKAWA MOTOMAN DX100 Instruction Manual

Programming pendant cheat sheet
Hide thumbs Also See for MOTOMAN DX100:
Table of Contents

Advertisement

166465-1CD
Auto-Axcess DI/E Digital
5

Operation

5.1

5.1.1 Welder Condition File

Table 5-1: Welder Output
RANGE
ADJUST
NO.
01
02
03
04
05
06
07
08
5
Operation

5.1 Set-Up Overview

Set-Up Overview
This chapter covers set-up information that is unique to the DX100/Miller
Auto-Axcess system. It covers:
• Setting the Welder Condition File
• Arc Start Files and Arc End Files
• Verifying the welder calibration
• Selecting weld programs
The Welder Condition file is set as follows (this has been preset by
Yaskawa Motoman):
POWER SUPPLY: A/V
<CURRENT OUTPUT
CHARS.>
+
1.00
REF. (V)
MEASURE (A)
0.52
1.16
2.57
3.85
5.12
6.39
8.71
12.81
• Although the robot teach pendant displays "A", "AC" or
"amps" in Arc Start Files, ARCON commands, etc., when
using the above calibration data, the values used are in
NOTE
units of INCHES/MIN., NOT AMPERAGE, and correspond
to the actual WIRE FEED SPEED of the wire feeder.
• The Digital Interface uses direct settings, no special
procedures like AutoCal are required.
5-1
<WELDING VOLTAGE OUTPUT>
+
1.00
REF. (V)
40
0.26
90
1.30
200
2.60
300
3.86
399
5.14
498
6.45
679
7.70
999
11.29
166465-1CD
MEASURE (V)
1.0
5.0
10.1
15.0
20.0
25.1
30.0
44.0
37/56